Programmable transmitter

 

  • Input for RTD, TC, mV, Ohm, potentiometer, mA and V
  • 2-wire supply > 16.5 V to Ex zone 0
  • Bipolar voltage input
  • Output for current, voltage and 2 relays
  • Universal supply by AC or DC
  1. Overview

  2. Technical details

  3. Accessories


Application

  • Linearized, electronic temperature measurement with RTD or TC sensor.
  • Conversion of linear resistance variation to a standard analog current / voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer.
  • Power supply and signal isolator for 2-wire transmitters.
  • Process control with 2 potential-free relay contacts which can be configured for advanced functions.
  • Galvanic separation of analog signals and measurement of floating signals.

Technical characteristics

  • Within a few seconds the user can program PR5116B to suit the specific application.
  • By way of the front push-button the input can be calibrated to the exact span of the process. Zero drift on the process signal can be adjusted by a single press of the front buttton.
  • A green front LED indicates normal operation and malfunction. A yellow LED is ON for each active output relay.
  • Continuous check of vital stored data for safety reasons.
  • 3-port 3.75 kVAC galvanic isolation.

Mounting / installation

  • Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without any distance between neighboring units, up to 42 devices can be mounted per meter.

Environmental Conditions

Operating temperature -20°C to +60°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP20

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 130 mm
Weight approx. 235 g
Wire size 1 x 2.5 mm2 stranded wire
Screw terminal torque 0.5 Nm
Vibration IEC 60068-2-6
2...13.2 Hz ±1 mm
13.2...100 Hz ±0.7 g

Common specifications

Supply

Supply voltage, universal 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC
Fuse 400 mA SB / 250 VAC
Max. required power ≤ 3 W

Isolation voltage

Isolation voltage, test / working 3.75 kVAC / 250 VAC
PELV/SELV IEC 61140

Response time

Temperature input, programmable (0...90%, 100...10%) 400 ms...60 s
mA / V input (programmable) 250 ms...60 s

Auxiliary supplies

2-wire supply (pin 54...52) 28...16.5 VDC / 0...20 mA
Programming Loop Link
Signal / noise ratio Min. 60 dB (0...100 kHz)
Accuracy Better than 0.05% of selected range
Signal dynamics, input 22 bit
Signal dynamics, output 16 bit
Auxiliary voltages: Reference voltage 2.5 VDC ±0.5% / 15 mA
EMC immunity influence < ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span

Input specifications

Common input specifications

Max. offset 50% of selected max. value

RTD input

RTD type Pt100, Ni100, lin. R
Cable resistance per wire 10 Ω (max. 50 Ω)
Sensor current Nom. 0.2 mA
Effect of sensor cable resistance (3-/4-wire) < 0.002 Ω / Ω
Sensor error detection Yes

TC input

Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5, LR
Cold junction compensation (CJC) < ±1.0°C
Sensor error current Nom. 30 μA
Sensor error detection Yes

Current input

Measurement range 0...100 mA
Min. measurement range (span) 4 mA
Input resistance: Supplied unit Nom. 10 Ω + PTC 10 Ω
Input resistance: Non-supplied unit RSHUNT = ∞, VDROP < 6 V
Sensor error detection Loop break 4...20 mA

Voltage input

Measurement range 0...250 VDC -2500...+2500 mV
Min. measurement range (span) 5 mV
Input resistance Nom. 10 MΩ (≤ 2.5 VDC) Nom. 5 MΩ (> 2.5 VDC)
> 5 MΩ (mV input)
Potentiometer via 2.5 V ref. 170 Ω

Output specifications

Current output

Signal range 0...20 mA
Min. signal range 10 mA
Load (@ current output) ≤ 600 Ω
Load stability ≤ 0.01% of span / 100 Ω
Current limit ≤ 28 mA
Sensor error indication Programmable 0...23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA

Voltage output

Signal range 0...10 VDC
Min. signal range 500 mV
Load (@ voltage output) ≥ 500 kΩ

Passive 2-wire mA output

Max. external 2-wire supply 29 VDC
Effect of external 2-wire supply voltage variation < 0.005% of span / V

Relay output

Relay functions Increasing / decreasing Window
Max. voltage 250 VRMS
Max. current 2 AAC
Max. AC power 500 VA
Max. load at 24 VDC 1 A
Sensor error reaction Break / Make / Hold / None
2-wire 4...20 mA output: Signal range 4...20 mA
Load stability, 4…20 mA output ≤ 0.01% of span / 100 Ω
of span = of the currently selected measurement range

Observed authority requirements

EMC 2014/30/EU
LVD 2014/35/EU
EAC TR-CU 020/2011

Approvals

ATEX 2014/34/EU KEMA 04ATEX1316 X
FM 3023092
UL UL 508 / C22.2 no. 14
EAC Ex TR-CU 012/2011 RU C-DK.GB08.V.00410
DNV-GL Marine Stand. f. Certific. No. 2.4
Your request has been sent successfully. - 0 Items on your list
Product description Quantity
Please specify variant(s) (see data sheet) - or indicate ‘Variant unknown’
Your contact information
Continue browsing
No products added
You have no products on your list...

When browsing product pages on this website, you have the possibility to add products to a list - and send your list to us, thereby requesting a quotation.
You add products to the list by clicking the "GET A QUOTE" button on the individual product pages.

When you have submitted the list, we will get back to you as quickly as possible.

If you don't submit the list, it will be visible to you on the website for 7 days (we will place a so-called' cookie on your pc or tablet).

We hope you will find the functionality useful. Go to the product pages to add products to your list.
Thank you for your request for a quotation.
We will get back to you by phone or email as soon as possible.