Isolation amplifier

 

  • Input galvanically separated from output and supply
  • Current or voltage input
  • Signal conversion
  • Current and voltage output
  • 24 VDC supply or universally supplied
  • Applicable in PELV/SELV circuits
  1. Overview +

  2. Technical details +

  3. Accessories +


Advanced features

  • Factory-calibrated measurement ranges for input and outputs in the 2204 can be selected by the internal DIP-switches without the need for recalibration.

Application

  • Signal isolator for analog current / voltage signals.
  • 1 : 1 or signal conversion of analog current /voltage signals within the ranges: 0...10 VDC or 0...50 mA on the input and 0...20 mA and 0...10 VDC in fixed ranges on the output.
  • Analog signal conditioning with microprocessor based gain and zero offset giving a response time of less than 25 ms.

Technical characteristics

  • Universally supplied units have a 3-port galvanic separation between input, supply, and output.
  • Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.

Environmental Conditions

  • Operating temperature

    -20°C to +60°C

  • Calibration temperature

    20...28°C

  • Relative humidity

    < 95% RH (non-cond.)

  • Protection degree

    IP50

Mechanical specifications

  • Dimensions (HxWxD)

    80.5 x 35.5 x 84.5 mm (D is without pins)

  • Weight DC / universally supplied

    110 g / 160 g

Common specifications

  • Supply

  • Supply voltage

    19.2...28.8 VDC

  • Supply voltage, universal

    21.6...253 VAC, 50...60 Hz or 19.2...300 VDC

  • Internal power dissipation

    ≤ 1.3 W (2204--D )

    ≤ 1.8 W (2204--P)

  • Isolation voltage

  • Isolation voltage, test / working

    3.75 kVAC / 250 VAC

  • PELV/SELV

    IEC 61140

  • Response time

  • Response time (0...90%)

    < 25 ms

  • Accuracy

    Better than 0.1% of sel. range

  • Signal / noise ratio

    Min. 60 dB

  • Temperature coefficient

    < ±0.01% of span / °C

  • Linearity error

    < 0.1% of span

  • Effect of supply voltage change

    < ±0.002% of span / %V

  • EMC immunity influence

    < ±0.5% of span

Input specifications

  • Common input specifications

  • Max. offset

    20% of max. value

  • Current input

  • Measurement range

    0...50 mADC

  • Min. measurement range (span)

    4 mA

  • Input resistance

    Nom. 50 Ω

  • Voltage input

  • Measurement range

    0...10 VDC

  • Min. measurement range (span)

    0.2 VDC

  • Input resistance

    10 MΩ

Output specifications

  • Current output

  • Signal range

    0...5 mA / 0...20 mA

  • Min. signal range

    4 mA / 16 mA

  • Load (@ current output)

    ≤ 600 Ω

  • Load stability

    ≤ 0.01% of span / 100 Ω

  • Current limit

    23...28 mA

  • of span

    = of the presently selected range

Observed authority requirements

  • EMC

    2014/30/EU

  • LVD

    2014/35/EU

  • EAC

    TR-CU 020/2011

Your request has been sent successfully. - 0 Items on your list
Product description Quantity
Please specify variant(s) (see data sheet) - or indicate ‘Variant unknown’
Your contact information
Continue browsing
No products added
You have no products on your list...

When browsing product pages on this website, you have the possibility to add products to a list - and send your list to us, thereby requesting a quotation.
You add products to the list by clicking the "GET A QUOTE" button on the individual product pages.

When you have submitted the list, we will get back to you as quickly as possible.

If you don't submit the list, it will be visible to you on the website for 7 days (we will place a so-called' cookie on your pc or tablet).

We hope you will find the functionality useful. Go to the product pages to add products to your list.
Thank you for your request for a quotation.
We will get back to you by phone or email as soon as possible.