Items 0
5343B
 

5343B

 

2-wire level transmitter

 

  • Potentiometer or Ohmic input
  • Programmable sensor error value
  • High measurement accuracy
  • Unique process calibration function
  • Programmable via standard PC
  1. Overview

  2. Technical details

  3. Accessories


Application

  • Conversion of resistance variation to standard analog current signals, e.g. from Ohmic level sensors or valve positions.
  • User-defined linearization function can be activated.

Technical characteristics

  • Within a few seconds the user can program PR5343B to measure within the defined Ohmic values.
  • Continuous check of vital stored data for safety reasons.
  • The transmitter is protected against polarity reversal.
  • PR5343B is configured to the current task by way of a PC, the PReset software and the communications interface Loop Link.
  • The PRelevel configuration tool included in the PReset software has been developed specifically for the configuration of level applications. Among other things, it contains a function for ”on line” measurement of input span as well as a linearization function for volume linear output from horizontal cylindrical tanks.

Mounting / installation

  • For DIN form B sensor head or DIN rail mounting with a special fitting.
  • NB: As I.S. / Ex barrier for 5343B we recommend 5104B, 5114B or 5116B.

Environmental Conditions

Operating temperature -40°C to +85°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree (encl./terminal) IP68 / IP00

Mechanical specifications

Dimensions Ø 44 x 20.2 mm
Weight approx. 50 g
Wire size 1 x 1.5 mm2 stranded wire
Screw terminal torque 0.4 Nm
Vibration IEC 60068-2-6
2...25 Hz ±1.6 mm
25...100 Hz ±4 g

Common specifications

Supply

Supply voltage 8.0...30 VDC
Internal power dissipation 25 mW…0.8 W

Response time

Response time (programmable) 0.33...60 s
Voltage drop 8.0 VDC
Warm-up time 5 min.
Programming Loop Link
Signal / noise ratio Min. 60 dB
Accuracy Better than 0.1% of selected range
Signal dynamics, input 19 bit
Signal dynamics, output 16 bit
Effect of supply voltage change < 0.005% of span / VDC
EMC immunity influence < ±0.5% of span

Input specifications

Common input specifications

Max. offset 50% of selected max. value

Linear resistance input

Measurement range / min. range (span) 0...100 kΩ / 1 kΩ
Cable resistance per wire (max.) 100 Ω
Sensor current > 25 μA, < 120 μA
Effect of sensor cable resistance (3-wire) < 0.002 Ω / Ω
Sensor error detection Yes
Min. measurement range 1 kΩ

Output specifications

Current output

Signal range 4…20 mA
Min. signal range 16 mA
Load (@ current output) ≤ (Vsupply - 8) / 0.023 [Ω]
Load stability ≤ 0.01% of span / 100 Ω
Sensor error indication Programmable 3.5…23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA

Common output specifications

Updating time 135 ms
*of span = of the presently selected range

Observed authority requirements

EMC 2014/30/EU
EAC TR-CU 020/2011

Approvals

ATEX 2014/34/EU KEMA 03ATEX1538
FM FM17US0013X
IECEx DEK 13.0036X
INMETRO DEKRA 13.0002 X
EAC Ex TR-CU 012/2011 RU C-DK.GB08.V.00410
DNV-GL Marine Stand. f. Certific. No. 2.4 V1-7-2
Your request has been sent successfully. - 0 Items on your list
Product description Quantity
Please specify variant(s) (see data sheet) - or indicate ‘Variant unknown’
Your contact information
Continue browsing
No products added
You have no products on your list...

When browsing product pages on this website, you have the possibility to add products to a list - and send your list to us, thereby requesting a quotation.
You add products to the list by clicking the "GET A QUOTE" button on the individual product pages.

When you have submitted the list, we will get back to you as quickly as possible.

If you don't submit the list, it will be visible to you on the website for 7 days (we will place a so-called' cookie on your pc or tablet).

We hope you will find the functionality useful. Go to the product pages to add products to your list.
Thank you for your request for a quotation.
We will get back to you by phone or email as soon as possible.