7501
Field mounted HART temperature transmitter
- RTD, TC, Ohm, and bipolar mV input and analog output
- High definition local operator interface (LOI) with 3 optical buttons
- Selectable red or white backlight
- Ex d explosion proof / flame proof in aluminum or 316 stainless steel version
- HART 7 functionality with HART 5 compatibility
High defintion display
- 0, 90, 180, & 270 degree position adjustments.
- Monitoring, programming and diagnostics view.
- Extensive diagnostics with flashing red or white backlight
- Supports 7 languages.
Local operator interface (LOI)
- 3 optical buttons; up, down and enter.
- Dynamically adaptive to wear or accumulation of dirt.
- Immune to interference from ambient light sources.
- Useable with or without gloves.
Configuration
- From the LOI through PR guided menu.
- PReset and HART modem.
- HHC, DCS or AMS via HART.
Mounting / installation
- For installation in zone 0, 1, 2 and zone 20, 21, 22 and in Class 1, Division 1 and 2 applications.
- Hardware assessed for use in SIL 2 applications.
- Mounting on 1.5”–2” pipe bracket or on wall / bulkhead.
Application
- Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
- HART communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
- Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
- Amplification of bipolar mV signals to standard 4...20 mA current signals.
- Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.
Technical characteristics
- NAMUR NE43 and NE89.
- HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
Declaration of Conformity
Environmental Conditions
| Operating temperature |
-40°C to +85°C (with silicone O-ring)
-20°C to +85°C (with FKM O-ring) |
| Storage temperature | -40°C to +85°C |
| Calibration temperature | 20...28°C |
| Relative humidity | 0...100% RH (condensing) |
| Protection degree | IP54 / IP66 / IP68 / type 4X |
Mechanical specifications
| Dimensions | Ø 110 mm |
| Dimensions (HxWxD), aluminum | 109.3 x 145 x 126 mm |
| Dimensions (HxWxD), stainless steel | 107.4 x 145 x 124 mm |
| Weight approx., aluminum / stainless steel | 1.3 / 2.8 kg |
| Wire size | 0.13 x1.5 mm2 / AWG 26...16 stranded wire |
| Screw terminal torque | 0.4 Nm |
| Vibration | IEC 60068-2-6 |
| 2...25 Hz | ±1.6 mm |
| 25...100 Hz | ±4 g |
| Display resolution | 96 x 64 pixels |
| Number of digits | 5 |
| Backlight | Selectable ON/OFF |
| Backlight color | Selectable white or red |
Common specifications
Supply |
|
| Supply voltage, DC: Ex ia, intrinsically safe | 10 (12 - with backlight)...30 VDC |
| Supply voltage, DC: Other | 10 (12 - with backlight)...35 VDC |
Isolation voltage |
|
| Isolation voltage, test / working | 1.5 kVAC / 50 VAC |
Response time |
|
| Response time (programmable) | 1...60 s |
| Signal / noise ratio | > 60 dB |
| Programming | HART |
| Start-up time, transmitter to display | Max. 5 s |
| Long-term stability, better than | ±0.1% of span / year |
| Accuracy | Better than 0.05% of selected range |
| Signal dynamics, input | 22 bit |
| Signal dynamics, output | 16 bit |
| EMC immunity influence | < ±0.1% of span |
| Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Common input specifications |
|
| Max. offset | 50% of selected max. value |
RTD input |
|
| RTD type | Pt50/100/200/500/1000; Ni50/100/120/1000 |
| Cable resistance per wire | 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy) |
| Sensor current | Nom. 0.2 mA |
Linear resistance input |
|
| Linear resistance min....max. | 0 Ω...7000 Ω |
TC input |
|
| Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
| Cold junction compensation (CJC) | Constant, internal or external via a Pt100 or Ni100 sensor |
Voltage input |
|
| Measurement range | -800...+800 mV |
| Min. measurement range (span) | 2.5 mV |
| Input resistance | 10 MΩ |
Output specifications
Current output |
|
| Signal range | 4…20 mA |
| Min. signal range | 16 mA |
| Load (@ current output) | ≤ (Vsupply - 10) / 0.023 [Ω] |
| Load resistance, with backlight | ≤ (Vsupply - 12) / 0.023 [Ω] |
| Sensor error indication | Programmable 3.5…23 mA |
| NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Common output specifications |
|
| Updating time | 440 ms |
| HART protocol revisions | HART 7 and HART 5 |
Observed authority requirements
| EMC | 2014/30/EU |
| EAC | TR-CU 020/2011 |
Approvals
| EU RO Mutual Recognition Type Approval | MRA0000009 |
| ATEX | DEKRA 15 ATEX 0058 X |
| IECEx | IECEx DEK 15.0039 X |
| FM | FM16US0009X / FM16CA0010X |
| CSA | 70024231 |
| INMETRO | DEKRA 15.0014 X |
| NEPSI | GYJ15.1336X, GYJ15.1337X and GYJ15.1338X |
| EAC Ex | RU C-DK.HA65.B.00355/19 |
| SIL | Hardware assessed for use in SIL applications |
277
USB HART modem
8550
7501 Blind plug M20, aluminum
8550-F
7501 Blind plug M20, aluminum
8550-S
7501 Blind plug M20, stainless
8550-SF
7501 Blind plug M20, stainless
8551
7501 Blind plug ½NPT, aluminum
8551-S
7501 Blind plug, stainless
8552
7501 Pipe-mounting bracket
8555
7501 Display spare part with LOI
8556
7501 Display spare part without LOI
8557
7501 Bracket spare part for display and transmitter
8558
7501 Bracket spare part for transmitter only[VIDEO] 7501 Field mounted HART temperature transmitter with display and optical buttons