You have no products on your list...
When browsing product pages on this website, you have the possibility to add products to a list - and send your list to us, thereby requesting a quotation.
You add products to the list by clicking the "GET A QUOTE" button on the individual product pages.
When you have submitted the list, we will get back to you as quickly as possible.
If you don't submit the list, it will be visible to you on the website for 7 days (we will place a so-called' cookie on your pc or tablet).
We hope you will find the functionality useful. Go to the product pages to add products to your list.
4179
Universal AC / DC transmitter
- Measures AC current and voltage signals
- Outputs passive or active current signals
- Programming, process monitoring and diagnostics via 45xx
- Response time < 0.75 s and excellent accuracy better than 0.3%
- Universally powered by 21.6…253 VAC / 19.2...300 VDC
Application
- The 0...5 AAC RMS range makes it possible to accurately measure a typical current transformer.
- The 0...300 VAC RMS range allows accurate supply voltage monitoring.
- The 4179 measures standard input ranges, and can be freely configured to customer-defined input range.
- Converts narrow AC current / voltage inputs to wide bipolar or unipolar outputs, e.g. 0...1 VAMS input = ±10 volt or 4...20 mA output with a minimum span of 0.5 AAC RMS or 0.5 VAC RMS.
- The detachable 45xx displays provide enhanced diagnostics.
- Configurable input limits control the output value for increased safety.
- The 4179 has been designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.
Technical characteristic
- The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
- Possibility of output safety feedback by selecting S4...20 mA output.
- The current output can drive up to 800 Ohms, with an adjustable response time of 0.0…60.0 seconds.
- Exceptional mA output load stability of <0.001% of span / 100 Ohm.
- Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
- Meets the NAMUR NE43 recommendations, allowing the control system to easily detect an input error.
- Tested to a high 2.3 kVAC, 3-port galvanic isolation level.
- Excellent signal to noise ratio of > 60 dB.
Mounting / installation / programming
- Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
- Configuration, monitoring, 2-point process calibration and more are accomplished using PR's 45xx detachable displays.
- All programming can be password-protected.
Environmental Conditions
| Operating temperature | -20°C to +60°C |
| Storage temperature | -20°C to +85°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-cond.) |
| Protection degree | IP20 |
| Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
| Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
| Dimensions (HxWxD) w/ 4501/4511 | 109 x 23.5 x 116 / 131 mm |
| Weight approx. | 155 g |
| Weight incl. 4501 / 4511 (approx.) | 170 g / 185 g |
| DIN rail type | DIN EN 60715/35 mm |
| Wire size | 0.13...2.08 mm2 AWG 26...14 stranded wire |
| Screw terminal torque | 0.5 Nm |
| Vibration | IEC 60068-2-6 |
| 2...13.2 Hz | ±1 mm |
| 13.2...100 Hz | ±0.7 g |
Common specifications
Supply |
|
| Supply voltage, universal | 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC |
| Max. required power | ≤ 1.8 W nom. |
| Internal power dissipation | ≤ 2.5 W |
Isolation voltage |
|
| Test voltage | 2.3 kVAC |
| Working voltage | 250 VAC (reinforced) / 500 VAC (basic) |
Response time |
|
| Response time (0...90%, 100...10%) | < 0.75 s |
| Programming | PR 45xx |
| Signal dynamics, input | 20 bit |
| Signal dynamics, output | 18 bit |
| Signal / noise ratio | > 60 dB |
| Output referred common mode rejection ratio | 0.02 ppm / VHz |
| Accuracy | Better than 0.3% of selected range* |
| EMC immunity influence | < ±0.5% of span* |
| Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span* |
| of span | = of selected standard range |
Input specifications
Current input |
|
| Signal range | 0...5 AAC / 40...400 Hz |
| Maximum input limit | 6.00 AAC @ 40°C |
| Programmable measurement ranges | 0...0.5; 0…1; 0…2.5 & 0...5 AAC |
| Custom configurable signal range | 0...5 AAC /40...400 Hz |
| Min. measurement range (span) | 0.5 AAC |
| Input resistance | Nom. < 0.07 Ω |
Voltage input |
|
| Signal range | 0...300 VAC / 40...400 Hz |
| Programmable measurement ranges | 0...0.5, 0...1, 0...2.83, 0…5, 0…120, 0…230 & 0…300 VAC |
| Custom configurable signal range | 0...300 VAC / 40...400 Hz |
| Min. measurement range (span) | 0.5 VAC |
| Input resistance | Nom. 3 MΩ || 100 pF |
Output specifications
Active unipolar and bipolar mA output |
|
| Programmable ranges |
0...20, 4...20 and S4...20 mA
±10 and ±20 mA Direct or Inverted Action |
| Load (@ current output) | ≤ 800 Ω |
| V-curve function, active signals, 100-0-100% | 20-0-20 mA |
Passive 2-wire mA output |
|
| Programmable ranges |
0...20 and 4...20 mA
Direct or Inverted action |
| V-curve function, 100-0-100% | 20-0-20 mA |
| External loop supply | 3.5...30 V |
Current output |
|
| Signal range |
0...23 mA (unipolar)
-23...+23 mA (bipolar) |
| Current limit |
≤ 28 mA (unipolar)
± 28 mA (bipolar) |
| Load stability | ≤ 0.001% of span / 100 Ω |
| Response time, programmable | 0.0...60.0 s |
Voltage output |
|
| Programmable signal ranges |
0/0.2...1; 0/1...5 ; 0/2...10; 1...0.2/0; 5...1/0; 10...2/0 V
±1, ±5 and ±10 V Direct or Inverted action |
| V-curve function, 100-0-100% | 1-0-1, 5-0-5 and 10-0-10 V |
| Load (@ voltage output) | ≥ 500 kΩ |
| Response time, programmable | 0.0...60.0 s |
Observed authority requirements
| EMC | 2014/30/EU |
| LVD | 2014/35/EU |
| RoHS | 2011/65/EU |
Approvals
| UL | UL 508 / C22.2 no. 14 |
| SIL | Hardware assessed for use in SIL applications |
NB
| * / ** | For custom configurable signal ranges, general accuracy and EMC specifications are 0.3% of full scale |
4501
Display / programming front
4511
Communication enabler
4590
ConfigMate
7005
Shunt resistor 0.1 Ω
7006
Shunt resistor 1 Ω
7014
Shunt resistor 0.5 Ω
7029
Shunt resistor 0.2 Ω
7030
Shunt resistor 0.1 Ω for DIN rail mounting
8510
8 unit 4511 Modbus cable
8511
4511 Y-splitter Modbus cable
8513
RJ45 Modbus termination
8514
3 X RJ45 female Y-splitter
8515
RJ45 female to female cable adapter
8516
RJ45 female to female shielded cable adabter