5116B
Programmable transmitter
- Input for RTD, TC, mV, Ohm, potentiometer, mA and V
- 2-wire supply > 16.5 V to Ex zone 0
- Bipolar voltage input
- Output for current, voltage and 2 relays
- Universal supply by AC or DC
Application
- Linearized, electronic temperature measurement with RTD or TC sensor.
- Conversion of linear resistance variation to a standard analog current / voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer.
- Power supply and signal isolator for 2-wire transmitters.
- Process control with 2 potential-free relay contacts which can be configured for advanced functions.
- Galvanic separation of analog signals and measurement of floating signals.
Technical characteristics
- Within a few seconds the user can program PR5116B to suit the specific application.
- By way of the front push-button the input can be calibrated to the exact span of the process. Zero drift on the process signal can be adjusted by a single press of the front buttton.
- A green front LED indicates normal operation and malfunction. A yellow LED is ON for each active output relay.
- Continuous check of vital stored data for safety reasons.
- 3-port 3.75 kVAC galvanic isolation.
Mounting / installation
- Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without any distance between neighboring units, up to 42 devices can be mounted per meter.
Declaration of Conformity
Environmental Conditions
| Operating temperature | -20°C to +60°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-cond.) |
| Protection degree | IP20 |
Mechanical specifications
| Dimensions (HxWxD) | 109 x 23.5 x 130 mm |
| Weight approx. | 235 g |
| Wire size | 0.13...2.08 mm2 AWG 26...14 stranded wire |
| Screw terminal torque | 0.5 Nm |
| Vibration | IEC 60068-2-6 |
| 2...13.2 Hz | ±1 mm |
| 13.2...100 Hz | ±0.7 g |
Common specifications
Supply |
|
| Supply voltage, universal | 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC |
| Fuse | 400 mA SB / 250 VAC |
| Max. required power | 2.4 W |
| Max. power dissipation | 2.0 W |
Isolation voltage |
|
| Isolation voltage, test / working | 3.75 kVAC / 250 VAC |
Response time |
|
| Temperature input, programmable (0...90%, 100...10%) | 400 ms...60 s |
| mA / V input (programmable) | 250 ms...60 s |
Auxiliary supplies |
|
| 2-wire supply (pin 54...52) | 28...16.5 VDC / 0...20 mA |
| Programming | Loop Link |
| Signal / noise ratio | Min. 60 dB (0...100 kHz) |
| Accuracy | Better than 0.05% of selected range |
| Signal dynamics, input | 22 bit |
| Signal dynamics, output | 16 bit |
| Auxiliary voltages: Reference voltage | 2.5 VDC ±0.5% / 15 mA |
| EMC immunity influence | < ±0.5% of span |
| Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Common input specifications |
|
| Max. offset | 50% of selected max. value |
RTD input |
|
| RTD type | Pt100, Ni100, lin. R |
| Cable resistance per wire | 10 Ω (max. 50 Ω) |
| Sensor current | Nom. 0.2 mA |
| Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
| Sensor error detection | Yes |
TC input |
|
| Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
| Cold junction compensation (CJC) | < ±1.0°C |
| Sensor error current | Nom. 30 μA |
| Sensor error detection | Yes |
Current input |
|
| Measurement range | 0...100 mA |
| Min. measurement range (span) | 4 mA |
| Input resistance: Supplied unit | Nom. 10 Ω + PTC 10 Ω |
| Input resistance: Non-supplied unit | RSHUNT = ∞, VDROP < 6 V |
| Sensor error detection | Loop break 4...20 mA |
Voltage input |
|
| Measurement range |
0...250 VDC
-2500...+2500 mV |
| Min. measurement range (span) | 5 mV |
| Input resistance |
Nom. 10 MΩ (≤ 2.5 VDC)
Nom. 5 MΩ (> 2.5 VDC) > 5 MΩ (mV input) |
| Potentiometer via 2.5 V ref. | 170 Ω |
Output specifications
Current output |
|
| Signal range | 0...20 mA |
| Min. signal range | 10 mA |
| Load (@ current output) | ≤ 600 Ω |
| Load stability | ≤ 0.01% of span / 100 Ω |
| Current limit | ≤ 28 mA |
| Sensor error indication | Programmable 0...23 mA |
| NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Passive 2-wire mA output |
|
| Signal range | 4...20 mA |
| Load stability | ≤ 0.01% of span / 100 Ω |
| Max. external 2-wire supply | 29 VDC |
| Effect of external 2-wire supply voltage variation | < 0.005% of span / V |
Voltage output |
|
| Signal range | 0...10 VDC |
| Min. signal range | 500 mV |
| Load (@ voltage output) | ≥ 500 kΩ |
Relay output |
|
| Relay functions |
Increasing / decreasing
Window |
| Max. voltage | 250 VAC / VDC |
| Max. current | 2 A |
| Max. AC power | 500 VA |
| Max. DC current, resistive load ≤ 30 VDC | 2 ADC |
| Max. DC current, resistive load > 30 VDC | See manual for details |
| Sensor error reaction | Break / Make / Hold / None |
| of span | = of the currently selected measurement range |
Observed authority requirements
| EMC | 2014/30/EU |
| LVD | 2014/35/EU |
| RoHS | 2011/65/EU |
| EAC | TR-CU 020/2011 |
Approvals
| ATEX 2014/34/EU | KEMA 04ATEX1316 X |
| FM | 3023092 |
| UL | UL 508 / C22.2 no. 14 |
| EAC Ex TR-CU 012/2011 | RU C-DK.GB08.V.00410 |
| DNV-GL Marine | Stand. f. Certific. No. 2.4 |
5909
Loop Link communications interface
5910Ex
CJC connector
7007
2-digit digital potentiometer
7008
3-digit digital potentiometer
7009
10-turn potentiometer, 200 Ω
7011
Dial for 10-turn potentiometer
7012
1-turn potentiometer, 1 kΩ
7020
Knob for 1-turn potentiometer
7020A
Knob for 10-turn potentiometer
7028
10-turn potentiometer, 2 kΩ
7423
Ceramic socket for Pt100 sensor
7430B
Pt100 cable sensor
7430C
Pt100 cable sensor
7440
Thermowell for PR 7400 Pt100 sensor
8201L
Power wire