System 9000 backplane

 

  1. Overview +

  2. Technical details +


Application

  • The 7916 backplane is a compact and robust solution that enables a safe and easy connection of PR system 9000 IS device signals into standard automation systems.
  • Standard automation system cables and connectors are used to link the backplane to the I/O cards.
  • The backplane can be used for Direct, Redundant, Duplicate signalling including HART I/O System connectivity (HART MUX).
  • The system 9000 devices isolate and convert AI, AO, DI and DO signals coming from, or going to the I.S. classified area, and routes those signals to a system automation I/O card.
  • The system 9000 units maintain a SIL2 level of functional safety, even when mounted in the backplane solution.

Technical characteristics

  • Robust, compact high-end design that holds 16 system 9000 units.
  • Digital output indicates status of the 9000 devices and primary/back-up power supplies.
  • Flexible 24 VDC supply voltage and redundant power supply connection solution.

Mounting / installation / programming

  • Flexible horizontal/vertical panel or wall mounting in the Safe or Zone 2 / Div 2 areas.
  • System 9000 devices easily snap ON and OFF using piano keys, and devices can be hot-swapped.
  • Tag number and ID labels are easily mounted and read by using the dedicated piano key spacer.
  • Wide temperature operation range: -20...+60°C.
  • Backplane selection guide can be found at www.prelectronics.com/backplane

Environmental Conditions

  • Operating temperature

    -20°C to +60°C

  • Storage temperature

    -40°C to +85°C

  • Relative humidity

    < 95% RH (non-cond.)

  • Installation in

    Pollution degree 2 & meas. / overvoltage cat. II

Mechanical specifications

  • Dimensions (HxWxD)

    144 x 443 x 141 mm

  • Wire size

    2.5 mm2 / AWG 12

    (Supply 1 / 2 and status relay connectors)

Common specifications

  • Supply

  • Supply voltage

    20...31.2 VDC (24 DC nom.)

  • Max. required power

    ≤ 60 W

  • Isolation voltage

  • Isolation voltage, test / working

    500 VAC / 50 VAC

    (Basic isolation between supply 1 & 2 and status relay)

  • Replaceable fuses

    Fuse F1 & F2: 3.15 A SB, 250 V, type TR5

Output specifications

  • Status relay

  • Max. voltage

    32 V (Zone 2 / Div. 2 area)

    42 V (Safe area)

  • Max. current

    100 mA (Zone 2 / Div. 2 area)

    100 mA (Safe area)

Observed authority requirements

  • EMC

    2014/30/EU

  • EAC

    TR-CU 020/2011

Approvals

  • UL

    UL 508 / C22.2 no. 14

  • ATEX 2014/34/EU

    DEKRA 13ATEX0136X

  • IECEx

    DEK 13.0044X

  • FM

    0003049918-C

Din anmodning om et tilbud er nu sendt til os. - 0 Produkter på din liste
Produktbeskrivelse Antal
Anfør venligst produktvariant - (se data ark på produktsiden). Eller anfør "variant ukendt".
Din kontaktinformation
Fortsæt med at browse
Du har ikke tilføjet produkter til listen
Du har ikke tilføjet nogen produkter...

På vores produktsider har du mulighed for at klikke på "FÅ ET TILBUD" knappen og tilføje produktet til en liste - og sende listen til os.
Når du sender listen, anmoder du om at få et uforpligtende tilbud på de listede produkter.

Når du har sendt listen, vender vi tilbage til dig så hurtigt som muligt.

Har du ikke indsendt listen, vil du kunne se den i 7 dage her på hjemmesiden (vi lægger en cookie på din pc eller tablet).

Vi håber, du får glæde af funktionaliteten. Gå til produktsiderne for at tilføje produkter til din liste.

Tak for din forespørgsel.
Vi vil kontakte dig per telefon eller email så hurtigt som muligt.