  • 230 or 115 VAC primary voltage
  • 24 VDC output voltage
  • Double isolation by 3.75 kVAC
  • 48 Watt output power, short circuit-protected
  • Thermal protection against overload
  1. Resumen + -

  2. Datos técnicos + -

  3. Accessorios + -


Advanced features

  • The power supply is based on primary switchmode technology to achieve a high efficiency.
  • An internally mounted potentiometer allows for a ±5% adjustment of the output voltage.

Application

  • General 24 VDC supply for equipment that requires a stabilised DC voltage.
  • Two units can be connected in series to achieve a plus / minus supply or a higher output voltage.
  • Separation of circuits in safety installations according to the PELV/SELV norm.
  • Galvanic isolation between the primary and the secondary voltage is achieved through the double-isolated safety transformer.

Technical characteristics

  • A green LED in the front of the module indicates an active primary voltage.
  • Input circuit protected with a thermal fuse.
  • DC output short circuit protection with current limiter.
  • Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.

Ficha técnica y manuales


Ficha técnica

Manuales

Documentación complementaria


Declaración UE de conformidad

Nota de seguridad


Nota de seguridad

Homologaciones y certificados


Declaración EAC

Declaración LVD EAC

Metrology Pattern Approval (MPA)

Environmental Conditions

Operating temperature -20°C to +60°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP30

Mechanical specifications

Dimensions (HxWxD) 80.5 x 35.5 x 84.5 mm (D is without pins)
Weight approx. 210 g

Common specifications

Supply

Fuse 1 A SB / 250 VAC
Max. required power 60 VA

Isolation voltage

Isolation voltage, test / working 3.75 kVAC / 250 VAC
PELV/SELV IEC 61140
Effect of supply voltage change < 1% (±10%)
Efficiency ≥ 80%
Thermal overload protection 100°C
Power derating 1% / °Camb. (Tamb. > 40°C)
Transient stability (10%-max. load) < 500 mV
Temperature coefficient 0.05% / °C
EMC immunity influence < ±0.5%

Input specifications

Supply voltage 207...253 VAC 102.4...132.2 VAC
Frequency 50...60 Hz

Output specifications

Current output

Current limit Nom. 2.5 A (electronic)
Output voltage 24 VDC
Adjustment ±5%
Output power 48 W (max.)
Output current 2 A / 24 VDC
Load effect, (0-max. load) < 1.5% / A
Output ripple ≤ 40 mVRMS (100 kHz)

Observed authority requirements

EMC 2014/30/EU
LVD 2014/35/EU
RoHS 2011/65/EU
EAC TR-CU 020/2011
EAC LVD TR-CU 004/2011
 

¿Es útil esta información?

 

Puntúenos

Su solicitud ha sido enviada con éxito 0 artículos en su lista
Su información de contacto
Por favor, introduce tu nombre
Por favor, introduce tus apellidos
Por favor, introduce una dirección de correo electrónico válida
Por favor, introduce un número de teléfono válido. Utilice sólo números.
Por favor, introduce el nombre de tu puesto
Por favor, introduce el nombre de tu empresa
Por favor, introduce la dirección de tu empresa
Por favor, introduce un código postal válido
Por favor, introduce una ciudad
Seleccione país
Lea y acepte la política de privacidad de PR electronics.
No has añadido ningún producto a tu petición de oferta
Cuando navegues por la web, puedes añadir productos a la petición de oferta con sólo hacer clic en "Añadir a la oferta" en la página de cada producto. Una vez incluidos todos los productos necesarios, envíanos la petición y recibirás la oferta en 24 horas. Si no se envía, permanecerá disponible en la web durante 21 días. Esperamos que esta función te resulte útil.
Gracias por solicitar un presupuesto. Nos pondremos en contacto por teléfono o por correo electrónico en 24 horas.

¿Necesitas ayuda?

Si necesitas ayuda, contacta con nosotros

¡Mantente informado!

Regístrate aquí para recibir nuestro boletín de noticias