Advanced features

  • The 5223 transmitter can be configured with a standard PC and the Loop Link communications unit, or delivered fully configured.

Application

  • The f/I function performs frequency to current and voltage conversion.
  • The f/f function can be used for pulse division or multiplication and as a buffer collecting fast pulse trains.
  • A scale factor may be entered in all functions. Using both digital inputs, pulse addition or subtraction are possible.
  • The frequency generator function is used as e.g. a time base or clock generator.
  • Input and supply polarity reversal protection.
  • Current and voltage output signals galvanically separated from the supply and the inputs.
  • Programmable digital outputs including NPN, PNP or relay options.

Technical characteristics

  • 5 front LEDs, indicating f1 and f2 active inputs (not NPN), Dig.out.1 and 2 active outputs, and a programmable error signal.
  • Analog current output can be configured to any current within 0...20 mA range.
  • Voltage output range is selectable between 0...10 VDC and 0...1 VDC by use of internal jumpers.
  • Input range:

    Frequency: 0...20,000 Hz

    Sensor types: NAMUR, tacho, NPN, PNP, TTL, S0, contact

  • Output range:

    Current and voltage output: 0...20 mA / 0...10 V

    Relay outputs: 0...20 Hz

    NPN and PNP output as f/f: 0...1000 Hz

    NPN and PNP output as generator: 0...20,000 Hz

Ficha técnica y manuales


Ficha técnica

Manuales

Manuales en ruso

Documentación complementaria


Declaración UE de conformidad

Configuraciones por defecto

Nota de seguridad


Nota de seguridad

Homologaciones y certificados


Declaración EAC

Declaración LVD EAC

Metrology Pattern Approval (MPA), Russia

Environmental Conditions

Operating temperature -20°C to +60°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP20

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 130 mm
Weight approx. 240 g
DIN rail type DIN 46277
Wire size 1 x 2.5 mm2 stranded wire
Screw terminal torque 0.5 Nm

Common specifications

Supply

Supply voltage, universal 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC
Fuse 400 mA SB / 250 VAC
Max. required power 3.5 W
Internal power dissipation 3 W

Isolation voltage

Isolation voltage, test / working 3.75 kVAC / 250 VAC
Power-up delay 0...999 s
Warm-up time 1 min.
Programming Loop Link
Signal / noise ratio Min. 60 dB
Response time, analog < 60 ms + period
Response time, digital output < 50 ms + period
Signal dynamics, output 16 bit
Effect of supply voltage change < 0.005% of span / VDC
Auxiliary voltage: NAMUR supply 8.3 VDC ±0.5 VDC / 8 mA
S0 supply 17 VDC / 20 mA
NPN / PNP supply 17 VDC / 20 mA
Special supply (programmable) 5...17 VDC / 20 mA
Temperature coefficient < ±0.01% of span / °C
Linearity error < 0.1% of span
EMC immunity influence < ±0.5%

Input specifications

Common input specifications

Max. offset 90% of selected max. frequency
Measurement range 0...20 kHz
Min. measurement range 0.001 Hz
Max. frequency, with input filter ON 50 Hz
Min. period time with input filter ON 20 ms
Input types NAMUR acc. to DIN 19234 Tacho
NPN / PNP
2-phase encoder
TTL
S0 acc. to DIN 43864

Output specifications

Common output specifications

Updating time 20 ms

Current output

Signal range 0...20 mA
Min. signal range 5 mA
Load (@ current output) ≤ 600 Ω
Load stability ≤ 0.01% of span / 100 Ω
Current limit < 23 mA

Voltage output

Signal range 0...10 VDC
Min. signal range 250 mV
Load (@ voltage output) ≥ 500 kΩ

Relay output

Max. switching frequency 20 Hz
Max. voltage 250 VRMS
Max. current 2 AAC
Max. AC power 100 VA
Max. load at 24 VDC 1 A
Other output types Active outputs (NPN / PNP) f/f converter output
Frequency generator
of span = of the presently selected range

Observed authority requirements

EMC 2014/30/EU
LVD 2014/35/EU
RoHS 2011/65/EU
EAC TR-CU 020/2011
EAC LVD TR-CU 004/2011

 

Need support to select the right product for your application?

Our sales engineers are ready to help specify the right device to meet your needs.

 

Reach out by phone to get in touch with us straight away – or use the contact form or quick quote function to send your RFQ directly from the website. You’ll get a response within 24 hours on normal business days.

 

You can expect to get a confirmed delivery date via email within 2 days after we have received your order.

 

As soon as your package leaves our warehouse, you’ll receive tracking details via email. And if you have any questions along the way we’re just a phone call or email away.

 

State-of-the-art manufacturing

State-of-the-art manufacturing

Our 8,500 sqm integrated and automated manufacturing campus in Denmark covers the entire value-chain from design and development to manufacturing. It allows us to design and optimize for testing and manufacturing thereby constantly driving quality up and costs down.

 

Dedicated Presales / Aftersales

Dedicated Presale / Aftersales
Our more than 80 dedicated sales engineers can help specify the right device for your application. Backed by our 9 subsidiaries and more than 40 dedicated partners, we are directly accessible in more than 40 countries around the world.

 

Find a PR location close to you

 

Product reliability

Product reliability
Although we’d always like to be top of mind, we recognize our job is mainly to provide peace of mind. Install & Forget® is our way of saying that once installed, our devices will continue to perform even in the toughest environments. And we are not afraid to back that statement up with commitments.

 

Product deployment

Product deployment
Our devices are intuitive and simple to configure. Once installed they visualize rich diagnostics data, allowing the operator to plan preventative maintenance, maximizing process up-time.

 

 

Smart products

Smart products
Many of our devices are designed to accommodate current and future communication enablers, providing the operator with multifunctional capabilities that extends into the future.

 

Check out our range of communication interfaces

 

Smart products

 

Su solicitud ha sido enviada con éxito 0 artículos en su lista
Su información de contacto

Información de la empresa

Por favor, introduce el nombre de tu empresa
Por favor, introduce la dirección de tu empresa
Por favor, introduce un código postal válido
Por favor, introduce una ciudad
Seleccione país

Tu información

Por favor, introduce tu nombre
Por favor, introduce tus apellidos
Por favor, introduce una dirección de correo electrónico válida
Por favor, introduce un número de teléfono válido. Utilice sólo números.
Por favor, introduce el nombre de tu puesto
Lea y acepte la política de privacidad de PR electronics.
Recibirás una respuesta en 24 horas
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

A mistake has occurred. Please call us instead

No has añadido ningún producto a tu petición de oferta
Cuando navegues por la web, puedes añadir productos a la petición de oferta con sólo hacer clic en "Añadir a la oferta" en la página de cada producto. Una vez incluidos todos los productos necesarios, envíanos la petición y recibirás la oferta en 24 horas. Si no se envía, permanecerá disponible en la web durante 21 días. Esperamos que esta función te resulte útil.
Gracias por solicitar un presupuesto. Nos pondremos en contacto por teléfono o por correo electrónico en 24 horas.
Service Red

Si necesitas ayuda, contacta con nosotros

Service Red
Newsletter Icon Red

Regístrate aquí para recibir nuestro boletín de noticias

Newsletter Icon Red