6337A
 

2-wire HART transmitter

 

6337A

 

  • 1- or 2-channel converter for RTD, TC, Ohm, and bipolar mV signals
  • 2 analogue inputs and 5 device variables with status available
  • HART protocol revision selectable from HART 5 or HART 7
  • Hardware assessed for use in SIL applications
  • Mounting on a DIN rail in Safe Area or Zone 2/22
  1. Resumen + -

  2. Datos técnicos + -

  3. Accessorios + -


Application

  • Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
  • HART communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
  • Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
  • Amplification of bipolar mV signals to standard 4...20 mA current signals.
  • Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.

Technical characteristics

  • HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
  • The HART 7 protocol offers:
    ∙ Long Tag numbers of up to 32 characters.
    ∙ Enhanced Burst Mode and Event notification with time stamping.
    ∙ Device variable and status mapping to any dynamic variable PV, SV, TV or QV.
    ∙ Process signal trend measurement with logs and summary data.
    ∙ Automatic event notification with time stamps.
    ∙ Command aggregation for higher communication efficiency.
  • 6337A is designed according to strict safety requirements and is therefore suitable for applications in SIL installations.
  • Continuous check of vital stored data.
  • Meeting the NAMUR NE21 recommendations, the 6337A HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the 6337A meets NAMUR NE43 and NE89 recommendations.

Mounting / installation

  • DIN rail mounting with up to 84 channels per meter.
  • Configuration via standard HART communication interfaces or by PR 5909 Loop Link.
  • The 6337A can be mounted in zone 2, 22 / Class I, Division 2, Groups A, B, C, D.

Ficha técnica y manuales


Ficha técnica

Manuales

Manuales en ruso

Homologaciones y certificados


Certificado ATEX

Certificado IECEx

Certificado CSA

Certificado FM

Declaración EAC

Certificado EAC

Metrology Pattern Approval (MPA), Belarus

Metrology Pattern Approval (MPA), Kazakhstan

Metrology Pattern Approval (MPA), Russia

Documentación complementaria


Declaración UE de conformidad

Declaración CCC

Informe FMEDA

Declaración SIL

Certificado HART

Nota de seguridad

Environmental Conditions

Operating temperature -40°C to +85°C
Storage temperature -40°C to +85°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP20

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 104 mm
Weight (1 / 2 channels) 150 / 200 g
DIN rail type DIN EN 60715/35 mm
Wire size 0.13...2.08 mm2 AWG 26...14 stranded wire
Screw terminal torque 0.5 Nm

Common specifications

Supply

Supply voltage 8.0...35 VDC
Internal power dissipation, 1 / 2 ch. 19 mW...0.8 / 1.6 W

Isolation voltage

Isolation voltage, test / working 1.5 kVAC / 50 VAC

Response time

Response time (programmable) 1...60 s
Voltage drop 8.0 VDC
Signal / noise ratio > 60 dB
Accuracy Better than 0.05% of selected range
EMC immunity influence < ±0.1% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span

Input specifications

Common input specifications

Max. offset 50% of selected max. value

RTD input

RTD type Pt50/100/200/500/1000; Ni50/100/120/1000
Cable resistance per wire 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)
Sensor current Nom. 0.2 mA

Linear resistance input

Linear resistance min....max. 0 Ω...7000 Ω

TC input

Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5
Cold junction compensation (CJC) Constant, internal or external via a Pt100 or Ni100 sensor

Voltage input

Measurement range -800...+800 mV
Min. measurement range (span) 2.5 mV
Input resistance 10 MΩ

Output specifications

Current output

Signal range 4…20 mA
Min. signal range 16 mA
Load (@ current output) ≤ (Vsupply - 8) / 0.023 [Ω]
Sensor error indication Programmable 3.5…23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA

Common output specifications

Updating time 440 ms
HART protocol revisions HART 7 and HART 5

Observed authority requirements

EMC 2014/30/EU
ATEX 2014/34/EU
RoHS 2011/65/EU
EAC TR-CU 020/2011
EAC Ex TR-CU 012/2011

Approvals

ATEX KEMA 09ATEX0148 X
IECEx KEM 10.0084X
CSA 1125003
c FM us FM17US0013X
EAC Ex RU C-DK.HA65.B.00355/19
SIL Hardware assessed for use in SIL applications
 

¿Es útil esta información?

 

Puntúenos

Su solicitud ha sido enviada con éxito 0 artículos en su lista
Su información de contacto
Por favor, introduce tu nombre
Por favor, introduce tus apellidos
Por favor, introduce una dirección de correo electrónico válida
Por favor, introduce un número de teléfono válido. Utilice sólo números.
Por favor, introduce el nombre de tu puesto
Por favor, introduce el nombre de tu empresa
Por favor, introduce la dirección de tu empresa
Por favor, introduce un código postal válido
Por favor, introduce una ciudad
Seleccione país
Lea y acepte la política de privacidad de PR electronics.
No has añadido ningún producto a tu petición de oferta
Cuando navegues por la web, puedes añadir productos a la petición de oferta con sólo hacer clic en "Añadir a la oferta" en la página de cada producto. Una vez incluidos todos los productos necesarios, envíanos la petición y recibirás la oferta en 24 horas. Si no se envía, permanecerá disponible en la web durante 21 días. Esperamos que esta función te resulte útil.
Gracias por solicitar un presupuesto. Nos pondremos en contacto por teléfono o por correo electrónico en 24 horas.

¿Necesitas ayuda?

Si necesitas ayuda, contacta con nosotros

¡Mantente informado!

Regístrate aquí para recibir nuestro boletín de noticias