Items 0
5334B
 

5334B

 

2-wire programmable transmitter

 

  • TC input
  • High measurement accuracy
  • Galvanic isolation
  • Programmable sensor error value
  • For DIN form B sensor head mounting
  1. Overview

  2. Technical details

  3. Accessories


Application

  • Linearized temperature measurement with TC sensor.
  • Amplification of bipolar mV signals to a 4...20 mA signal, optionally linearized according to a defined linearization function.

Technical characteristics

  • Within a few seconds the user can program PR5334B to measure temperatures within all TC ranges defined by the norms.
  • Cold junction compensation (CJC) with a built-in temperature sensor.
  • Continuous check of vital stored data for safety reasons.

Mounting / installation

  • For DIN form B sensor head mounting.
  • NB: As Ex barrier we recommend 5104B, 5114B, or 5116B.

Environmental Conditions

Operating temperature -40°C to +85°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree (encl./terminal) IP68 / IP00

Mechanical specifications

Dimensions Ø 44 x 20.2 mm
Weight approx. 50 g
Wire size 1 x 1.5 mm2 stranded wire
Screw terminal torque 0.4 Nm
Vibration IEC 60068-2-6
2...25 Hz ±1.6 mm
25...100 Hz ±4 g

Common specifications

Supply

Supply voltage 7.2...30 VDC
Internal power dissipation 25 mW…0.8 W

Isolation voltage

Isolation voltage, test / working 1.5 kVAC / 50 VAC

Response time

Response time (programmable) 1...60 s
Voltage drop 7.2 VDC
Warm-up time 5 min.
Programming Loop Link
Signal / noise ratio Min. 60 dB
EEprom error check < 3.5 s
Accuracy Better than 0.05% of selected range
Signal dynamics, input 18 bit
Signal dynamics, output 16 bit
Effect of supply voltage change < 0.005% of span / VDC
EMC immunity influence < ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span

Input specifications

Common input specifications

Max. offset 50% of selected max. value

TC input

Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5, LR
Cold junction compensation (CJC) < ±1.0°C
Sensor error detection Yes
Sensor error current: When detecting / else Nom. 33 μA / 0 μA

Voltage input

Measurement range -12...150 mV
Min. measurement range (span) 5 mV
Input resistance 10 MΩ

Output specifications

Current output

Signal range 4…20 mA
Min. signal range 16 mA
Load (@ current output) ≤ (Vsupply - 7.2) / 0.023 [Ω]
Load stability ≤ 0.01% of span / 100 Ω
Sensor error indication Programmable 3.5…23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA

Common output specifications

Updating time 440 ms
*of span = of the presently selected range

Observed authority requirements

EMC 2014/30/EU
EAC TR-CU 020/2011

Approvals

ATEX 2014/34/EU KEMA 06ATEX0062X
IECEx DEK 13.0035X
INMETRO DEKRA 13.0001 X
CCOE P337392/2
EAC Ex TR-CU 012/2011 RU C-DK.GB08.V.00410
DNV-GL Marine Stand. f. Certific. No. 2.4
Your request has been sent successfully. - 0 Items on your list
Product description Quantity
Please specify variant(s) (see data sheet) - or indicate ‘Variant unknown’
Your contact information
Continue browsing
No products added
You have no products on your list...

When browsing product pages on this website, you have the possibility to add products to a list - and send your list to us, thereby requesting a quotation.
You add products to the list by clicking the "GET A QUOTE" button on the individual product pages.

When you have submitted the list, we will get back to you as quickly as possible.

If you don't submit the list, it will be visible to you on the website for 7 days (we will place a so-called' cookie on your pc or tablet).

We hope you will find the functionality useful. Go to the product pages to add products to your list.
Thank you for your request for a quotation.
We will get back to you by phone or email as soon as possible.