Items 0
5114A
 
 

5114A

 

Programmable transmitter

 

  • Input for RTD, TC, mV, linear resistance, mA, and V
  • 3-port 3.75 kVAC galvanic isolation
  • Current and voltage output
  • Universal voltage supply
  • 1- and 2-channel versions
  • Loop supply > 17.1 V
  1. Overview +

  2. Technical details +

  3. Accessories +


Advanced features

  • The 5114 transmitter can be configured using the PReset software and the Loop Link communications unit.

Application

  • Jumper selectable inputs for current/voltage or temperature.
  • Programmable current (0...100 mA) and voltage (0...250 VDC) inputs.
  • Linearized, electronic temperature measurement.
  • Conversion of linear resistance variation e.g, from solenoids and butterfly valves or linear movements with attached potentiometer.
  • 17.1 VDC loop and 2.5 VDC potentiometer supplies.
  • Automatic 4- / 3-wire or programmable 2-wire cable compensation.
  • Configurable sensor error detection including NAMUR NE43.

Technical characteristics

  • Active or Passive current output and selectable voltage output.
  • Separation of circuits in PELV/SELV installations.

Environmental Conditions

  • Operating temperature

    -20°C to +60°C

  • Calibration temperature

    20...28°C

  • Relative humidity

    < 95% RH (non-cond.)

  • Protection degree

    IP20

Mechanical specifications

  • Dimensions (HxWxD)

    109 x 23.5 x 130 mm

  • Weight approx.

    225 g

  • DIN rail type

    DIN 46277

  • Wire size

    1 x 2.5 mm2 stranded wire

  • Screw terminal torque

    0.5 Nm

Common specifications

  • Supply

  • Supply voltage, universal

    21.6...253 VAC, 50...60 Hz or 19.2...300 VDC

  • Fuse

    400 mA SB / 250 VAC

  • Max. required power

    2.1 W / 2.8 W (1 / 2 ch.)

  • Isolation voltage

  • Isolation voltage, test / working

    3.75 kVAC / 250 VAC

  • PELV/SELV

    IEC 61140

  • Response time

  • Temperature input, programmable (0...90%, 100...10%)

    400 ms...60 s

  • mA / V input (programmable)

    250 ms...60 s

  • Auxiliary supplies

  • 2-wire supply (pin 44...42 and 54...52)

    28...17.1 VDC / 0...20 mA

  • Programming

    Loop Link

  • Signal / noise ratio

    Min. 60 dB (0...100 kHz)

  • Accuracy

    Better than 0.05% of selected range

  • Updating time

    115 ms (temperature input)

    75 ms (mA / V / mV input)

  • Signal dynamics, input

    22 bit

  • Signal dynamics, output

    16 bit

  • Auxiliary voltages: Reference voltage

    2.5 VDC ±0.5% / 15 mA

  • EMC immunity influence

    < ±0.5% of span

  • Extended EMC immunity: NAMUR NE21, A criterion, burst

    < ±1% of span

Input specifications

  • Common input specifications

  • Max. offset

    50% of selected max. value

  • RTD input

  • RTD type

    Pt100, Ni100, lin. R

  • Cable resistance per wire

    10 Ω (max.)

  • Sensor current

    Nom. 0.2 mA

  • Effect of sensor cable resistance (3-/4-wire)

    < 0.002 Ω / Ω

  • Sensor error detection

    Yes

  • TC input

  • Thermocouple type

    B, E, J, K, L, N, R, S, T, U, W3, W5, LR

  • Cold junction compensation (CJC)

    < ±1.0°C

  • Sensor error current

    Nom. 30 μA

  • Sensor error detection

    Yes

  • Current input

  • Measurement range

    0...100 mA

  • Min. measurement range (span)

    4 mA

  • Input resistance: Supplied unit

    Nom. 10 Ω + PTC 10 Ω

  • Input resistance: Non-supplied unit

    RSHUNT = ∞, VDROP < 6 V

  • Voltage input

  • Measurement range

    0...250 VDC

    -150...+150 mV

  • Min. measurement range (span)

    5 mV

  • Input resistance

    Nom. 10 MΩ (≤ 2.5 VDC)

    Nom. 5 MΩ (> 2.5 VDC)

    Nom. 10 MΩ (mV input)

Output specifications

  • Current output

  • Signal range

    0...20 mA

  • Min. signal range

    10 mA

  • Load (@ current output)

    ≤ 600 Ω

  • Load stability

    ≤ 0.01% of span / 100 Ω

  • Current limit

    ≤ 28 mA

  • Sensor error indication

    Programmable 0...23 mA

  • NAMUR NE43 Upscale/Downscale

    23 mA / 3.5 mA

  • Passive 2-wire mA output

  • Signal range

    4...20 mA

  • Load stability

    ≤ 0.01% of span / 100 Ω

  • Max. load resistance [Ω]

    (Vsupply-3.5)/0.023 A

  • Max. external 2-wire supply

    29 VDC

  • Effect of external 2-wire supply voltage variation

    < 0.005% of span / V

  • Voltage output

  • Signal range

    0...10 VDC

  • Min. signal range

    500 mV

  • Load (@ voltage output)

    ≥ 500 kΩ

  • of span

    = of the presently selected range

Observed authority requirements

  • EMC

    2014/30/EU

  • LVD

    2014/35/EU

  • RoHS

    2011/65/EU

  • EAC

    TR-CU 020/2011

Approvals

  • DNV-GL Marine

    Stand. f. Certific. No. 2.4

Your request has been sent successfully. - 0 Items on your list
Product description Quantity
Please specify variant(s) (see data sheet) - or indicate ‘Variant unknown’
Your contact information
Continue browsing
No products added
You have no products on your list...

When browsing product pages on this website, you have the possibility to add products to a list - and send your list to us, thereby requesting a quotation.
You add products to the list by clicking the "GET A QUOTE" button on the individual product pages.

When you have submitted the list, we will get back to you as quickly as possible.

If you don't submit the list, it will be visible to you on the website for 7 days (we will place a so-called' cookie on your pc or tablet).

We hope you will find the functionality useful. Go to the product pages to add products to your list.
Thank you for your request for a quotation.
We will get back to you by phone or email as soon as possible.