5223B
 

Programmable f/I-f/f converter

 

5223B

 

  • Pulse calculator / frequency generator
  • Galvanic isolation
  • ATEX I.S. version
  • Analog current and voltage output
  • PNP / NPN output, optional relays
  • Universal supply
  1. Panoramica + -

  2. Dati tecnici + -

  3. Accessori + -


Advanced features

  • The 5223 transmitter can be configured with a standard PC and the Loop Link communications unit, or delivered fully configured.

Application

  • The f/I function performs frequency to current and voltage conversion.
  • The f/f function can be used for pulse division or multiplication and as a buffer collecting fast pulse trains.
  • A scale factor may be entered in all functions. Using both digital inputs, pulse addition or subtraction are possible.
  • The frequency generator function is used as e.g. a time base or clock generator.
  • Input and supply polarity reversal protection.
  • Current and voltage output signals galvanically separated from the supply and the inputs.
  • Programmable digital outputs including NPN, PNP or relay options.
  • ATEX units have input for mechanical contact and NAMUR inductive proximity sensor.

Technical characteristics

  • 5 front LEDs, indicating f1 and f2 active inputs (not NPN), Dig.out.1 and 2 active outputs, and a programmable error signal.
  • Analog current output can be configured to any current within 0...20 mA range.
  • Voltage output range is selectable between 0...10 VDC and 0...1 VDC by use of internal jumpers.
  • Input range:

    Frequency: 0...20,000 Hz

    Sensor types: NAMUR, tacho, NPN, PNP, TTL, S0

  • Output range:

    Current and voltage output: 0...20 mA / 0...10 V

    Relay outputs: 0...20 Hz

    NPN and PNP output as f/f: 0...1000 Hz

    NPN and PNP output as generator: 0...20,000 Hz

Scheda tecnica & manuali


Scheda tecnica

Manuali

Manuali in russo

Approvazioni & certificati


Certificato Ex

Dichiarazione EAC

Certificato EAC Ex

Metrology Pattern Approval (MPA)

Documentazione supplementare


Dichiarazione UE di conformità

Note di sicurezza


Note di sicurezza

Environmental Conditions

Operating temperature -20°C to +60°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP20

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 130 mm
Weight approx. 240 g
DIN rail type DIN 46277
Wire size 1 x 2.5 mm2 stranded wire
Screw terminal torque 0.5 Nm

Common specifications

Supply

Supply voltage, universal 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC
Fuse 400 mA SB / 250 VAC
Max. required power 3.5 W
Internal power dissipation 3 W

Isolation voltage

Isolation voltage, test / working 3.75 kVAC / 250 VAC
PELV/SELV IEC 61140
Power-up delay 0...999 s
Warm-up time 1 min.
Programming Loop Link
Signal / noise ratio Min. 60 dB
Response time, analog < 60 ms + period
Response time, digital output < 50 ms + period
Effect of supply voltage change < 0.005% of span / VDC
Temperature coefficient < ±0.01% of span / °C
Linearity error < 0.1% of span
NAMUR supply I.S. / Ex 8.9 VDC ±0.5 VDC / 8 mA
EMC immunity influence < ±0.5%

Input specifications

Common input specifications

Max. offset 90% of selected max. frequency
Measurement range 0...20 kHz
Min. measurement range 0.001 Hz
Min. pulse length 25 μs
Input types NAMUR acc. to DIN 19234

Output specifications

Common output specifications

Updating time 20 ms

Current output

Signal range 0...20 mA
Min. signal range 5 mA
Load (@ current output) ≤ 600 Ω
Load stability ≤ 0.01% of span / 100 Ω
Current limit < 23 mA

Voltage output

Signal range 0...10 VDC
Min. signal range 250 mV
Load (@ voltage output) ≥ 500 kΩ

Relay output

Max. switching frequency 20 Hz
Max. voltage 250 VRMS
Max. current 2 AAC
Max. AC power 100 VA (I.S. version 5223B)
Max. load at 24 VDC 1 A
Other output types Active outputs (NPN / PNP) f/f converter output
Frequency generator
of span = of the presently selected range

Observed authority requirements

EMC 2014/30/EU
LVD 2014/35/EU
EAC TR-CU 020/2011

Approvals

ATEX KEMA 04ATEX1001
EAC Ex RU C-DK.GB08.V.00410
 

Hai trovato utili queste informazioni?

 

Dai una valutazione

La vostra richiesta è stata inviata con successo 0 prodotti nella tua lista
I vostri contatti
Inserisci il tuo nome
Inserisci il tuo cognome
Inserisci un indirizzo di posta elettronica valido
Inserisci un numero di telefono valido. Usa solo numeri.
Inserisci la posizione lavorativa
Inserisci il nome della tua azienda
Inserisci il tuo indirizzo aziendale
Inserisci un Cap valido
Inserisci la città
Selezionare il paese
Leggi e accetta la politica sulla Privacy di PR electronics.
Non hai aggiunto alcun prodotto al tuo elenco di preventivi
Durante la visita del nostro sito Web, sarà possibile aggiungere prodotti a un elenco di preventivi semplicemente facendo clic su "Aggiungi all'elenco dei preventivi" nelle singole pagine dei prodotti. Una volta inclusi tutti i prodotti pertinenti, inviaci l'elenco e otterrai un preventivo entro 24 ore. Se non invii l'elenco, sarà accessibile sul sito Web per 21 giorni. Speriamo che troverai utile la funzionalità.
Grazie per aver richiesto un preventivo. Ti risponderemo telefonicamente o via e-mail entro 24 ore.

Bisogno di aiuto?

Se hai bisogno di assistenza, contattaci sarai sempre il benvenuto

Resta aggiornato!