2-wire HART transmitter
PR 6335D
- RTD, TC, Ohm, or mV input
- Extremely high measurement accuracy
- HART 5 protocol
- Can be installed in Ex zone 0
- 1- or 2-channel version
Application
- Linearized temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor.
- Difference or average temperature measurement of 2 resistance or TC sensors.
- Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level sensors.
- Amplification of a bipolar mV signal to a standard 4...20 mA current signal.
- Connection of up to 15 channels to a digital 2-wire signal with HART communication.
Technical characteristics
- Within a few seconds the user can program PR6335D to measure temperatures within all ranges defined by the norms.
- The RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.
- The 6335D provides the required failure data (SFF and PFDAVG) for SIL applications as per IEC 61508 / IEC 61511.
- A limit can be programmed on the output signal.
- Continuous check of vital stored data for safety reasons.
- Sensor error detection according to the guidelines in NAMUR NE89.
Mounting / installation
- Mounted vertically or horizontally on a DIN rail. Using the 2-channel version up to 84 channels per metre can be mounted.
- Configuration via standard HART communication interfaces or by PR 5909 Loop Link.
- The 6335D can be mounted in zone 0, 1, 2 and zone 21, 22 including M1 / Class I/II/ III, Division 1, Groups A, B, C, D.
Data sheet & Manuals
Data sheet
- 6335D.pdf
- Latest version
Manuals
- 6335V116_UK.pdf
- 6335V115_UK.pdf
- 6335V114_UK.pdf
- 6335V113_UK.pdf
- 6335V112_UK.pdf
- 6335V111_UK.pdf
- 6335V110_UK.pdf
- 6335V109.pdf
- 6335V108.pdf
- 6335V107.pdf
- 6335V106.pdf
- 6335V105.pdf
- Previous versions
- Latest version
Manuals in Russian
- 6335V116_RU.pdf
- 6335V115_RU.pdf
- 6335V114_RU.pdf
- 6335V113_RU.pdf
- 6335V112_RU.pdf
- 6335V111_RU.pdf
- 6335V110_RU.pdf
- 6335L108_RU.pdf
- 6335L107_RU.pdf
- Previous versions
- Latest version
Approvals & Certificates
ATEX certificate
- 6335D_20ATEX0108X_issue1.pdf
- 6335D_20ATEX0108X_issue0.pdf
- 6335D_09ATEX0148X_issue7.pdf
- 6335D_09ATEX0148X_issue6.pdf
- 6335D_09ATEX0148X_issue5.pdf
- 6335D_09ATEX0148X_issue4.pdf
- 6335D_09ATEX0148_issue3.pdf
- 6335D_09ATEX0148_issue2.pdf
- 6335D_09ATEX0148_issue1.pdf
- Previous versions
- Latest version
IECEx certificate
- 6335DIEC_200063X_issue1.pdf
- 6335DIEC_200063X_issue0.pdf
- 6335DIEC_100084X_issue5.pdf
- 6335DIEC_100084X_issue4.pdf
- 6335DIEC_100084X_issue3.pdf
- 6335DIEC_100084X_issue1.pdf
- 6335DIEC_100084X_issue0.pdf
- Previous versions
- Latest version
CSA certificate
- 533x_633x_CSA.pdf
- Latest version
FM certificate
- 53xx_633x_FM17US0013X.pdf
- 53xx_633x_FM_2D5A7.pdf
- Previous versions
- Latest version
INMETRO certificate
- INMETRO_5335_5337_6335_6337_230011X_issue1.pdf
- INMETRO_5335_5337_6335_6337_230011X_issue0.pdf
- Previous versions
- Latest version
EAC declaration
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Latest version
EAC declaration
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Belarus
- MPA_Belarus.pdf
- Latest version
Metrology Pattern Approval (MPA), Kazakhstan
- MPA_Kazakhstan.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 6335DoC_EU_103_UK.pdf
- 6335DoC_EU_102_UK.pdf
- 6335DoC_EU_101_UK.pdf
- 6335DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 6335DoC_UKCA_100_UK.pdf
- Latest version
CCC statement
- 5000_6000_series_CCC_statement.pdf
- Latest version
FMEDA report
- FMEDA_6335_R026V3R2.pdf
- Latest version
SIL certificate
- 5335_6335_5337_6337_7501_SIL1_declaration_Potmeter_V2.pdf
- 5335_6335_5337_6337_7501_SIL2_declaration_V2.pdf
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Safety note
View variants
Environmental Conditions
| Operating temperature | |
| Storage temperature | |
| Calibration temperature | |