Universal AC / DC transmitter
PR 4179
- Measures AC current and voltage signals
- Outputs passive or active current signals
- Programming, process monitoring and diagnostics via PR 4500
- Response time < 0.75 s and excellent accuracy better than 0.3%
- Universally powered by 21.6…253 VAC / 19.2...300 VDC
Application
- The 0...5 AAC RMS range makes it possible to accurately measure a typical current transformer.
- The 0...300 VAC RMS range allows accurate supply voltage monitoring.
- The 4179 measures standard input ranges, and can be freely configured to customer-defined input range.
- Converts narrow AC current / voltage inputs to wide bipolar or unipolar outputs, e.g. 0...1 VAC RMS input = ±10 volt or 4...20 mA output with a minimum span of 0.5 AAC RMS or 0.5 VAC RMS.
- Configurable input limits control the output value for increased safety.
- The 4179 provides the required failure data (SFF and PFDAVG) for SIL 2 applications as per IEC 61508 / IEC 61511.
- Failure rates for 4179 correspond to Performance Level “d” according to ISO-13849.
Technical characteristic
- The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
- Possibility of output safety feedback by selecting S4...20 mA output.
- The current output can drive up to 800 Ohms, with an adjustable response time of 0.0…60.0 seconds.
- Exceptional mA output load stability of <0.001% of span / 100 Ohm.
- Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
- Meets the NAMUR NE43 recommendations, allowing the control system to easily detect an input error.
- Tested to a high 2.3 kVAC, 3-port galvanic isolation level.
- Excellent signal to noise ratio of > 60 dB.
Mounting / installation / programming
- Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
- Configuration, monitoring, 2-point process calibration and more are accomplished using PR's 4500 series of detachable displays.
Note
- If you need an installation instruction in hard copy, you can order it for free when placing your order.
Data sheet & Manuals
Data sheet
- 4179.pdf
- Latest version
Manuals
- 4179V102_UK.pdf
- 4179V101_UK.pdf
- 4179V100_UK.pdf
- Previous versions
- Latest version
Manuals in Russian
- 4179V102_RU.pdf
- 4179V101_RU.pdf
- 4179V100_RU.pdf
- Previous versions
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 4179DoC_EU_101_UK.pdf
- 4179DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 4179DoC_UKCA_100_UK.pdf
- Latest version
SIL certificate
- 4179_4184_SILConformity01.pdf
- Latest version
Modbus configuration manual
- 4179_MCM_100.pdf
- Latest version
FMEDA report
- PR_4179_V1R1.pdf
- Latest version
ISO 13849 declaration
- 4179_ISO_13849_declaration.pdf
- Latest version
EAC LVD declaration
- 4000_EMC_data.pdf
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
China RoHS
- China_RoHS.pdf
- Latest version
Approvals & Certificates
UL certificate
- 4104_4179_4179B_4184_UL.pdf
- Latest version
EAC declaration
- EAC-Declaration.pdf
- Latest version
View variants
Environmental Conditions
| Operating temperature | -20°C to +60°C |
| Storage temperature | -20°C to +85°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-cond.) |
| Protection degree | IP20 |
| Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
| Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
| Dimensions (HxWxD) w/ PR 4500 | 109 x 23.5 x 131 mm |
| Weight approx. | 155 g |
| Weight incl. 4501 / 451x (approx.) | 170 g / 185 g |
| DIN rail type | DIN EN 60715/35 mm |
| Wire size | 0.13...2.08 mm2 AWG 26...14 stranded wire |
| Screw terminal torque | 0.5 Nm |
| Vibration | IEC 60068-2-6 |
| 2...13.2 Hz | ±1 mm |
| 13.2...100 Hz | ±0.7 g |
Common specifications
Supply |
|
| Supply voltage, universal | 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC |
| Max. required power | 1.6 W |
| Max. power dissipation - current measurement | 2.7 W |
| Max. power dissipation - voltage measurement | 1.6 W |
Isolation voltage |
|
| Test voltage | 2.3 kVAC |
| Working voltage | 250 VAC (reinforced) / 500 VAC (basic) |
Response time |
|
| Response time (0...90%, 100...10%) | < 0.75 s |
| Programming | PR 4500 communication interfaces |
| Signal dynamics, input | 20 bit |
| Signal dynamics, output | 18 bit |
| Signal / noise ratio | > 60 dB |
| Output referred common mode rejection ratio | 0.02 ppm / VHz |
| Accuracy | Better than 0.3% of selected range* |
| EMC immunity influence | < ±0.5% of span* |
| Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span* |
| of span | = of selected standard range |
Input specifications
Current input |
|
| Signal range | 0...5 AAC / 40...400 Hz |
| Maximum input limit | 6.00 AAC @ 40°C |
| Programmable measurement ranges | 0...0.5; 0…1; 0…2.5 & 0...5 AAC |
| Custom configurable signal range | 0...5 AAC /40...400 Hz |
| Min. measurement range (span) | 0.5 AAC |
| Input resistance | < 0.042 Ω (incl. terminals) |
Voltage input |
|
| Signal range | 0...300 VAC / 40...400 Hz |
| Programmable measurement ranges | 0...0.5, 0...1, 0...2.83, 0…5, 0…120, 0…230 & 0…300 VAC |
| Custom configurable signal range | 0...300 VAC / 40...400 Hz |
| Min. measurement range (span) | 0.5 VAC |
| Input resistance | Nom. 3 MΩ || 100 pF |
Output specifications
Active unipolar and bipolar mA output |
|
| Programmable ranges |
0...20, 4...20 and S4...20 mA
±10 and ±20 mA Direct or Inverted Action |
| Load (@ current output) | ≤ 800 Ω |
| V-curve function, active signals, 100-0-100% | 20-0-20 mA |
Passive 2-wire mA output |
|
| Programmable ranges |
0...20 and 4...20 mA
Direct or Inverted action |
| V-curve function, 100-0-100% | 20-0-20 mA |
| External loop supply | 3.5...30 V |
Current output |
|
| Signal range |
0...23 mA (unipolar)
-23...+23 mA (bipolar) |
| Current limit |
≤ 28 mA (unipolar)
± 28 mA (bipolar) |
| Load stability | ≤ 0.001% of span / 100 Ω |
| Response time, programmable | 0.0...60.0 s |
Voltage output |
|
| Programmable signal ranges |
0/0.2...1; 0/1...5 ; 0/2...10; 1...0.2/0; 5...1/0; 10...2/0 V
±1, ±5 and ±10 V Direct or Inverted action |
| V-curve function, 100-0-100% | 1-0-1, 5-0-5 and 10-0-10 V |
| Load (@ voltage output) | ≥ 500 kΩ |
| Response time, programmable | 0.0...60.0 s |
Observed authority requirements
| EMC | 2014/30/EU & UK SI 2016/1091 |
| LVD | 2014/35/EU & UK SI 2016/1101 |
| RoHS | 2011/65/EU & UK SI 2012/3032 |
| EAC | TR-CU 020/2011 |
Approvals
| c UL us, UL 508 | E248256 |
| SIL | Hardware assessed for use in SIL applications |
NB
| * / ** | For custom configurable signal ranges, general accuracy and EMC specifications are 0.3% of full scale |