2-wire programmable transmitter
PR 5333A
- RTD or Ohm input
- High measurement accuracy
- 3-wire connection
- Programmable sensor error value
- For DIN form B sensor head mounting
Application
- Linearized temperature measurement with Pt100...Pt1000 or Ni100...Ni1000 sensor.
- Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level sensors.
Technical characteristics
- Within a few seconds the user can program PR5333A to measure temperatures within all RTD ranges defined by the norms.
- The RTD and resistance inputs have cable compensation for 3-wire connection.
Mounting / installation
- For DIN form B sensor head or DIN rail mounting with the PR fitting type 8421.
Data sheet & Manuals
Data sheet
- 5333A.pdf
- Latest version
Manuals
- 5333V123_UK.pdf
- 5333V122_UK.pdf
- 5333V121_UK.pdf
- 5333V120_UK.pdf
- 5333V119_UK.pdf
- 5333V118_UK.pdf
- 5333V117_UK.pdf
- 5333V116_UK.pdf
- 5333V115_UK.pdf
- 5333V114_UK.pdf
- 5333V113_UK.pdf
- 5333V112_UK.pdf
- 5333V111_UK.pdf
- 5333V110_UK.pdf
- 5333V109.pdf
- 5333V108.pdf
- 5333V106.pdf
- Previous versions
- Latest version
Manuals in Russian
- 5333V123_RU.pdf
- 5333V122_RU.pdf
- 5333V121_RU.pdf
- 5333V120_RU.pdf
- 5333V119_RU.pdf
- 5333V118_RU.pdf
- 5333V117_RU.pdf
- 5333V116_RU.pdf
- 5333V115_RU.pdf
- 5333V114_RU.pdf
- 5333V113_RU.pdf
- 5333V112_RU.pdf
- 5333V111_RU.pdf
- 5333V110_RU.pdf
- 5333L109_RU.pdf
- Previous versions
- Latest version
Manuals in Portuguese (Brazil)
Approvals & Certificates
ATEX certificate
- 5333A_20ATEX0106X_issue1.pdf
- 5333A_20ATEX0106X_issue0.pdf
- 5333A_10ATEX0003X_issue3.pdf
- 5333A_10ATEX0003X_issue2.pdf
- 5333A_10ATEX0003X_issue1.pdf
- Previous versions
- Latest version
IECEx certificate
- 5333AIEC_200062X_issue1.pdf
- 5333AIEC_200062X_issue0.pdf
- 5333AIEC_130036X_issue1.pdf
- 5333AIEC_130036X_issue0.pdf
- Previous versions
- Latest version
CSA certificate
- 533x_633x_CSA.pdf
- Latest version
INMETRO certificate
- INMETRO_5333_5343_6333_230010X_issue1.pdf
- INMETRO_5333_5343_6333_230010X_issue0.pdf
- INMETRO_5333_5343_160014X_issue1.pdf
- INMETRO_5333_5343_160014X_issue0.pdf
- INMETRO_5333_5343_130002X.pdf
- Previous versions
- Latest version
DNV marine certificate
- DNV_2231_41xx_51xx_53xx.pdf
- Latest version
EAC declaration
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Latest version
EAC declaration
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Belarus
- MPA_Belarus.pdf
- Latest version
Metrology Pattern Approval (MPA), Kazakhstan
- MPA_Kazakhstan.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 5333DoC_EU_106_UK.pdf
- 5333DoC_EU_105_UK.pdf
- 5333DoC_EU_104_UK.pdf
- 5333DoC_EU_103_UK.pdf
- 5333DoC_EU_102_UK.pdf
- 5333DoC_EU_101_UK.pdf
- 5333DoC_EU_100_UK.pdf
- Previous versions
- Latest version
CCC statement
- 5000_6000_series_CCC_statement.pdf
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Safety note
- SN5300-2-120-2620.pdf
- SN5300-2-119-2605.pdf
- SN5300-2-118_2507.pdf
- SN5300-2-117-2420.pdf
- SN5300-2-116-2245.pdf
- SN5300-2-115-2202.pdf
- SN5300-2-114-2124.pdf
- SN5300-2-113-2016.pdf
- SN5300-2-112-1935.pdf
- SN5300-2-111-1924.pdf
- SN5300-2-110-1848.pdf
- SN5300-2-109-1749.pdf
- SN5300-2-108-1648.pdf
- SN5300-2-107-1614.pdf
- SN5300-106-1509.pdf
- Previous versions
- Latest version
View variants
Environmental Conditions
| Operating temperature | -40°C to +85°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-cond.) |
| Protection degree (encl./terminal) | IP68 / IP00 |
Mechanical specifications
| Dimensions | Ø 44 x 20.2 mm |
| Weight approx. | 50 g |
| Wire size | 1 x 1.5 mm2 stranded wire |
| Screw terminal torque | 0.4 Nm |
| Vibration | IEC 60068-2-6 |
| 2...25 Hz | ±1.6 mm |
| 25...100 Hz | ±4 g |
Common specifications
Supply |
|
| Supply voltage | 8.0...35 VDC |
| Internal power dissipation | 25 mW…0.8 W |
Response time |
|
| Response time (programmable) | 0.33...60 s |
| Voltage drop | 8.0 VDC |
| Warm-up time | 5 min. (1) |
| Programming | PR 5909 Loop Link communications interface |
| Signal / noise ratio | Min. 60 dB |
| Accuracy | Better than 0.1% of sel. range |
| Signal dynamics, input | 19 bit |
| Signal dynamics, output | 16 bit |
| Effect of supply voltage change | < 0.005% of span / VDC |
| EMC immunity influence | < ±0.5% of span |
Input specifications
Common input specifications |
|
| Max. offset | 50% of selected max. value |
RTD input |
|
| RTD type | Pt100…1000, Ni100...1000, lin. R |
| Cable resistance per wire | 10 Ω (max.) |
| Sensor current | > 0.2 mA, < 0.4 mA |
| Effect of sensor cable resistance (3-wire) | < 0.002 Ω / Ω |
| Sensor error detection | Yes |
Linear resistance input |
|
| Linear resistance min....max. | 0 Ω...10000 Ω |
Output specifications
Current output |
|
| Signal range | 4…20 mA |
| Min. signal range | 16 mA |
| Load (@ current output) | ≤ (Vsupply - 8) / 0.023 [Ω] |
| Load stability | ≤ 0.01% of span / 100 Ω |
| Sensor error indication | Programmable 3.5…23 mA |
| NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Common output specifications |
|
| Updating time | 135 ms |
| of span | = of the presently selected range |
I.S. / Ex marking
| ATEX | II 3 G Ex nA [ic] IIC T6...T4 Gc, II 3 G Ex ec [ic] IIC T6...T4 Gc, II 3 G Ex ic IIC T6...T4 Gc, II 3 D Ex ic IIIC Dc |
| IECEx | Ex nA [ic] IIC T6…T4 Gc, Ex ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc |
| CSA | Cl. I, Div. 2, Gp. A, B, C, D T6...T4, Ex nA[ic] IIC T6…T4 Gc |
| INMETRO | Ex ec [ic] IIC T6...T4 Gc, Ex ic IIC T6...T4 Gc, Ex ic IIIC Dc |
Observed authority requirements
| EMC | 2014/30/EU |
| ATEX | 2014/34/EU |
| RoHS | 2011/65/EU |
| EAC | TR-CU 020/2011 |
| EAC Ex | TR-CU 012/2011 |
Approvals
| DNV Marine | TAA0000101 |
| ATEX | DEKRA 20ATEX0106X |
| IECEx | DEK 20.0062X |
| CSA | 1125003 |
| INMETRO | DEKRA 23.0010X |
| EAC Ex | EAEU KZ 7500361.01.01.08756 |