HART transparent repeater
PR 9106A
- 24 VDC supply via power rail or connectors
- Active and passive mA input
- Active or passive output via the same two terminals
- Splitter function - 1 in and 2 out
- SIL2 / SIL3 Full Assessment and certified acc. to IEC 61508
Application
- 9106A is a 1- or 2-channel isolated 1:1 repeater.
- The device supplies 2-wire SMART transmitters and can also be used for 2-wire SMART current sources. HART & BRAIN protocols are supported and are transferred bi-directionally.
- 9106A can be mounted in the safe area or in zone 2 / Class I, Division 2, Groups A, B, C, D.
- For duplication/migration purposes, the outputs can be sent to two different DCS/PLC/HMI or any monitoring system.
- In safety applications (SIL loops), the 9106AxBx can be used as a splitter with the following output configuration:
• When using 9106AxBx in a SIL2 safety function, channel 1 is used for the safety loop. Channel 2 can be used for any non-safety device.
• For higher safety purposes (SIL 3), 9106AxBx can be used as a splitter for SIL 3 loops. Channel 1 and 2 are then connected to the same safety PLC, where channel 2 is used as a redundant diagnostic channel (for more information, consult the FMEDA Report and the Safety Manual).
Advanced features
- The detachable displays in the PR 4500 series and the green and red front LEDs indicate operation status for each channel.
- Monitoring of error events and cable breakage on input via the individual status relay and/or a collective electronic signal via the power rail.
- Failure rates for 9106A correspond to Performance Level “d” according to ISO-13849.
Technical characteristics
- High galvanic isolation of 2.6 kVAC.
- Fast response time <5 ms
- High accuracy better than 0.1%.
- 2-wire transmitter supply >16 V.
Mounting
- The devices can be mounted vertically or horizontally without distance between neighbouring units.
Data sheet & Manuals
Data sheet
- 9106A.pdf
- Latest version
Manuals
- 9106V112_UK.pdf
- 9106V002_111_UK.pdf
- 9106V002_110_UK.pdf
- 9106V002_109_UK.pdf
- 9106V002_108_UK.pdf
- 9106V002_107_UK.pdf
- 9106V002_106_UK.pdf
- 9106BV002_105_UK.pdf
- 9106BV002_104_UK.pdf
- 9106BV002_103_UK.pdf
- 9106BV002_102_UK.pdf
- 9106BV002_101_UK.pdf
- 9106BV001_100_UK.pdf
- 9106AV002_102_UK.pdf
- 9106AV002_101_UK.pdf
- 9106AV002_100_UK.pdf
- Previous versions
- Latest version
Manuals in Russian
- 9106V112_RU.pdf
- 9106V002_111_RU.pdf
- 9106V002_110_RU.pdf
- 9106V002_109_RU.pdf
- 9106V002_108_RU.pdf
- 9106V002_107_RU.pdf
- 9106V002_106_RU.pdf
- 9106BV002_105_RU.pdf
- 9106BV002_104_RU.pdf
- 9106BV002_103_RU.pdf
- 9106BV002_102_RU.pdf
- Previous versions
- Latest version
Manuals in Portuguese (Brazil)
- 9106V112_BR.pdf
- 9106V002_111_BR.pdf
- 9106V002_110_BR.pdf
- 9106V002_109_BR.pdf
- 9106V002_108_BR.pdf
- 9106V002_107_BR.pdf
- 9106V002_106_BR.pdf
- 9106BV002_105_BR.pdf
- 9106BV002_104_BR.pdf
- 9106BV002_103_BR.pdf
- 9106BV002_102_BR.pdf
- Previous versions
- Latest version
Manuals in Korean
- 9106V112_KR.pdf
- 9106V002_111_KR.pdf
- 9106V002_110_KR.pdf
- 9106V002_109_KR.pdf
- 9106V002_108_KR.pdf
- Previous versions
- Latest version
Safety manual (SIL)
- 9106_Safety_Manual_V3R0.pdf
- Latest version
Approvals & Certificates
ATEX certificate
- 9106A_11ATEX0244X_issue4.pdf
- 9106A_0014ATEX0101X_issue2.pdf
- 9106A_0014ATEX0101X_issue1.pdf
- Previous versions
- Latest version
IECEx certificate
- 9106IEC_110084X_issue3.pdf
- Latest version
UKEX certificate
- 9106A_21UKEX0171X_issue0.pdf
- Latest version
FM certificate
- 9106_9107_FM16US0465X_FM16CA0213X.pdf
- Latest version
INMETRO certificate
- 9106_INMETRO_230003X_issue1.pdf
- 9106_INMETRO_230003X_issue0.pdf
- Previous versions
- Latest version
UL certificate
CCC certificate
- 9106_CCC_2025_11.pdf
- 9106_CCC_2023_04.pdf
- 9106_CCC_2020_11.pdf
- Previous versions
- Latest version
KCs certificate
- 9106A_KCs_21_AV4BO_0169X.pdf
- Latest version
DNV marine certificate
- DNV_9xxx_4510_4511.pdf
- 9000_DoC_DNV.pdf
- Previous versions
- Latest version
ClassNK certificate
- ClassNK-TA24034M_91xx_92xx_94xx.pdf
- Latest version
SIL certificate
- 9106_002_SIL.pdf
- Latest version
EAC declaration
EAC declaration
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 9106DoC_EU_104_UK.pdf
- 9106DoC_EU_103_UK.pdf
- 9106DoC_EU_102_UK.pdf
- 9106DoC_EU_101_UK.pdf
- 9106DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 9106DoC_UKCA_100.pdf
- Latest version
Modbus configuration manual
- 9106_MCM_102.pdf
- 9106_MCM_101.pdf
- 9106_MCM_100.pdf
- Previous versions
- Latest version
Assessment
- AssessmentReport_PR_2312098_V1R0_Series_9000.pdf
- Latest version
FMEDA report
- PR_9106_9107_060319_R025_FMEDA_V2R1.pdf
- Latest version
ISO 13849 declaration
- 9106_ISO_13849_declaration.pdf
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Safety note
EAC LVD declaration
View variants
Environmental Conditions
| Operating temperature | -20°C to +60°C |
| Storage temperature | -20°C to +85°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-cond.) |
| Protection degree | IP20 |
| Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
| Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
| Dimensions (HxWxD) w/ PR 4500 | 109 x 23.5 x 131 mm |
| Weight approx. | 250 g |
| DIN rail type | DIN EN 60715/35 mm |
| Wire size | 0.13...2.08 mm2 AWG 26...14 stranded wire |
| Screw terminal torque | 0.5 Nm |
| Vibration | IEC 60068-2-6 |
| 2...13.2 Hz | ±1 mm |
| 13.2...100 Hz | ±0.7 g |
Common specifications
Supply |
|
| Supply voltage | 19.2...31.2 VDC |
| Fuse | 1.25 A SB / 250 VAC |
| Max. required power | ≤ 1.1 W / ≤ 1.9 W (1 ch. / 2 ch.) |
| Max. power dissipation, 1 / 2 ch. | ≤ 0.8 W / ≤ 1.2 W |
Isolation voltage |
|
| Test /working: Input to any | 2.6 kVAC / 300 VAC reinforced isolation |
| Analog output to supply | 2.6 kVAC / 300 VAC reinforced isolation |
| Status relay to supply | 1.5 kVAC / 150 VAC reinforced isolation |
Response time |
|
| Response time (0...90%, 100...10%) | < 5 ms |
| Programming | PR 4500 communication interfaces |
| Signal dynamics, input | Analog signal chain |
| Signal dynamics, output | Analog signal chain |
| SMART bi-directional communication frequency range | 0.5...7.5 kHz |
| Signal / noise ratio | > 60 dB |
| Accuracy | Better than 0.1% of sel. range |
| mA, absolute accuracy | ≤ ±16 μA |
| mA, temperature coefficient | ≤ ±1.6 μA / °C |
| Effect of supply voltage change on output (nom. 24 VDC) | < ±10 μA |
| EMC immunity influence | < ±0.5% of span |
| Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Current input |
|
| Measurement range | 3.5...23 mA |
| 2-wire transmitter supply 9106A1x | >16 V / 20 mA |
| 2-wire transmitter supply 9106A2x | >15 V / 20 mA |
| Sensor error detection: Loop break 4...20 mA | < 1 mA |
| Input voltage drop, supplied unit | < 4 V @ 23 mA |
| Input voltage drop, non-supplied unit | < 6 V @ 23 mA |
Output specifications
Current output |
|
| Signal range | 3.5...23 mA |
| Load (@ current output) | ≤ 600 Ω |
| Load stability | ≤ 0.01% of span / 100 Ω |
| Current limit | ≤ 28 mA |
Passive 2-wire mA output |
|
| Effect of external 2-wire supply voltage variation | < 0.005% of span / V |
| Max. external 2-wire supply | 26 VDC |
Status relay |
|
| Relay function | Bistable, closed on fault* |
| Max. voltage | 125 VAC / 110 VDC |
| Max. current | 0.5 AAC / 0.3 ADC |
| Max. voltage - hazardous installation | 32 VDC / 32 VAC |
| Max. current - hazardous installation | 1 ADC / 0.5 AAC |
| of span | = normal measurement range 4...20 mA |
Observed authority requirements
| EMC | 2014/30/EU & UK SI 2016/1091 |
| LVD | 2014/35/EU & UK SI 2016/1101 |
| ATEX | 2014/34/EU & UK SI 2016/1107 |
| RoHS | 2011/65/EU & UK SI 2012/3032 |
| EAC | TR-CU 020/2011 |
| EAC LVD | TR-CU 004/2011 |
| EAC Ex | TR-CU 012/2011 |
Approvals
| ATEX | DEKRA 11ATEX0244 X |
| IECEx | DEK 11.0084X |
| UKEX | DEKRA 21UKEX0171X |
| c FM us | FM16US0465X / FM16CA0213X |
| INMETRO | DEKRA 23.0003X |
| c UL us, UL 61010-1 | E314307 |
| c UL us, UL 913 | E233311 (only 9106xxx-U9) |
| CCC | 2020322309003231 |
| KCs | 21_AV4BO_0169X (only 9106Axx-KCs) |
| EAC Ex | EAEU KZ 7500361.01.01.08756 |
| DNV Marine | TAA00000JD |
| ClassNK | TA24034M |
| SIL | SIL 2 / SIL 3 certified & fully assessed acc. to IEC 61508 |