Compact RTD temperature transmitter

 

PR 5802

 

  • RTD or Ohm input
  • Accuracy: Better than 0.1% of selected range
  • 2- / 3-wire RTD connection
  • Programmable sensor error value
  • Output 4...20 mA, with or without M12 connector
  1. Overview + -

  2. Technical details + -

  3. Accessories + -

Application

  • Linearized temperature measurement with Pt100...Pt1000, or Ni100...Ni1000 sensor.

  • Conversion of linear resistance variation to a standard analog current signal.

Technical characteristics

  • Within a few seconds the user can program PR5802 to measure temperatures within all RTD ranges defined by the norms.

  • The RTD and resistance inputs have cable compensation for 3-wire connection.

Mounting / installation

  • For tube mounting, e.g. M18 barrel housing or customer specific housing.

  • The unit is tested with an M12 connector, mounted in a steel housing and molded with Silgel 612 silicone molding compound. This is PR electronics' recommended method to comply with specifications and EMC data for EN 61326-1.

Data sheet & Manuals


Data sheet

Manuals

Supplementary documentation


PR default configurations

Download Software

Environmental Conditions

Operating temperature -40°C to +85°C
Storage temperature -40°C to +85°C
Relative humidity < 95% RH (non-cond.)

Mechanical specifications

Dimensions, PCB only (WxHxD) 5.0 x 15.50 x 38.0 mm
Dimensions (incl. M12 connector) 9.5 x 15.50 x 47.70 mm
Weight approx. 2.65 g 5802A1xx 4.05 g 5802A2xx

Common specifications

Supply

Supply voltage 8.0...35 VDC
Internal power dissipation 25 mW…0.8 W

Response time

Response time (programmable) 0.33...60 s
Voltage drop 8.0 VDC
Warm-up time 5 min. (1)
Programming PR 5909 Loop Link communications interface
Signal / noise ratio Min. 60 dB
Signal dynamics, input 19 bit
Signal dynamics, output 16 bit
Effect of supply voltage change < 0.005% of span / VDC
Accuracy Better than 0.1% of sel. range
EMC immunity influence < ±0.5% of span

Input specifications

Common input specifications

Max. offset 50% of selected max. value

RTD input

RTD type Pt100…1000, Ni100...1000, lin. R
Cable resistance per wire 10 Ω (max.)
Sensor current > 0.2 mA, < 0.4 mA
Effect of sensor cable resistance (3-wire) < 0.002 Ω / Ω
Sensor error detection Yes

Output specifications

Common output specifications

Updating time 135 ms

Current output

Signal range 4…20 mA
Min. signal range 16 mA
Load (@ current output) ≤ (Vsupply - 8) / 0.023 [Ω]
Load stability ≤ 0.01% of span / 100 Ω
Sensor error indication Programmable 3.5…23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA
of span = of the presently selected range

Observed authority requirements

RoHS 2011/65/EU
Your request has been sent successfully. 0 items on your list
Your contact information

Company information

Please insert your company name.
Please insert your company address
Please insert a valid zip code
Please insert a city
Please select country

Your information

First name
Please insert your last name
Please insert a valid email address
Please insert a valid phone number. Use only numbers.
Please insert your job title
Please read and agree with PR electronics’ Privacy Policy.
Get an answer within 24 hours
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

A mistake has occurred. Please call us instead

You have not added any products to your quote list
When browsing the website, you can add products to a quote list by simply clicking “Add to quote list" on the individual product pages. Once all relevant products are included, send the list to us and you will get a quotation within 24 hours. If you don't submit the list, it will be accessible on the website for 21 days. We hope you will find the functionality useful.