Pulse isolator

 

PR 5202A

 

  • 2 channels - 2 or 4 outputs
  • Dual output
  • 5-port 3.75 kVAC galvanic isolation
  • Cable error detection
  • Universal supply by AC or DC
UL List EAC CE Pr Rohs3 Guarantee
  1. Overview + -

  2. Technical details + -

Application

  • Pulse isolator for the supply of NAMUR sensors.
  • Pulse isolator for the detection of mechanical contacts.
  • One input signal can be used on two separate outputs.
  • A cable error alarm can be detected on a separate output.

Technical characteristics

  • PR5202A1 and 5202A2 have relays with change-over contacts or open NPN collectors.
  • PR5202A4 has 4 SPST relays, which are activated simultaneously two and two. Each relay can be programmed to the function N.O. or N.C.
  • Inputs, outputs and supply are floating and galvanically separated.

Mounting / installation

  • Mounted vertically or horizontally on a DIN rail. Up to 84 channels per meter can be mounted.

Data sheet & Manuals


Data sheet

Manuals

Manuals in Russian

Supplementary documentation


EU Declaration of Conformity

PR default configurations

Approvals & Certificates


UL certificate

EAC declaration

Metrology Pattern Approval (MPA), Russia

Environmental Conditions

Operating temperature -20°C to +60°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP20

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 130 mm
Weight approx. 230 g
Wire size 0.13...2.08 mm2 AWG 26...14 stranded wire
Screw terminal torque 0.5 Nm

Common specifications

Supply

Supply voltage, universal 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC
Fuse 400 mA SB / 250 VAC
Internal power dissipation ≤ 1.5 W (2 channels), 5202A1 and 5202A2 ≤ 2.0 W (2 channels), 5202A4
Max. required power ≤ 1.5 W (2 channels), 5202A1 and 5202A2 ≤ 2.0 W (2 channels), 5202A4

Isolation voltage

Isolation voltage, test / working 3.75 kVAC / 250 VAC
PELV/SELV IEC 61140

Auxiliary supplies

NAMUR supply 8 VDC / 8 mA
Programming Jumpers
EMC immunity influence < ±0.5%
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1%

Input specifications

Sensor types NAMUR according to EN 60947-5-6 / mechanical contact
Frequency range 0...5 kHz
Pulse length > 0.1 ms
Input resistance 1 kΩ
Trig level, signal < 1.2 mA, > 2.1 mA
Trig level, cable fault < 0.1 mA, > 6.5 mA

Output specifications

Relay output

Max. switching frequency 20 Hz
Max. voltage 250 VRMS
Max. current 2 AAC
Max. AC power 100 VA
Max. load at 24 VDC 1 A

NPN output

Max. switching frequency 5 kHz
Min. pulse length > 0.1 ms
Max. load, current / voltage 80 mA / 30 VDC
Voltage drop at 25 mA / 80 mA < 0.75 VDC / < 2.5 VDC

Observed authority requirements

EMC 2014/30/EU
LVD 2014/35/EU
EAC TR-CU 020/2011
EAC LVD TR-CU 004/2011

Approvals

c UL us, UL 508 UL-US-L231911-11-81903002-0
Your request has been sent successfully. 0 items on your list
Your contact information

Company information

Please insert your company name.
Please insert your company address
Please insert a valid zip code
Please insert a city
Please select country

Your information

First name
Please insert your last name
Please insert a valid email address
Please insert a valid phone number. Use only numbers.
Please insert your job title
Please read and agree with PR electronics’ Privacy Policy.
Get an answer within 24 hours
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

A mistake has occurred. Please call us instead

You have not added any products to your quote list
When browsing the website, you can add products to a quote list by simply clicking “Add to quote list" on the individual product pages. Once all relevant products are included, send the list to us and you will get a quotation within 24 hours. If you don't submit the list, it will be accessible on the website for 21 days. We hope you will find the functionality useful.
Thank you for requesting a quotation. We will get back to you by phone or email within 24 hours.