2-wire HART 7 temperature transmitter
PR 6437A
- RTD, TC, potentiometer, linear resistance and bipolar mV input
- Single or true dual inputs with sensor redundancy and drift detection
- Wide ambient operating temperature of -50 to +85°C
- Total accuracy from 0.014%
- 2.5 kVAC galvanic isolation
- Full assessment to IEC61508 : 2010 for use in SIL 2/3 applications
Application
- Temperature measurement of a wide range of TC and RTD types.
- Conversion of wide span linear resistance and potentiometer inputs to 4...20 mA.
- Conversion of bipolar mV signals to 4...20 mA.
- Integration into asset management schemes.
- Critical applications requiring superior accuracy and/or sensor redundancy and drift detection.
Technical characteristics
- True dual input transmitter, accepts the widest range of dual input combinations.
- Sensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, maintaining uptime.
- Sensor drift detection - alerts when sensor differential exceeds user-defined limits, for maintenance optimization.
- Dynamic variable mapping for process data in addition to the primary variable e.g. dual input features such as average, differential and min./max. tracking.
- Groundbreaking digital and analog signal accuracy over full input span and ambient conditions.
- Extensive sensor matching including Callendar Van Dusen and custom linearizations.
- Programmable input limits with runtime metering ensure maximum process traceability and sensor out of range protection.
- IEC 61508 : 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.
- Failure rates for 6437xxSx correspond to Performance Level “d” according to ISO-13849.
- Meets NAMUR NE21, NE43, NE44, NE89 and NE107 compliant diagnostics information.
Mounting / installation / programming
- DIN rail mounting with up to 84 inputs per meter.
- Configuration via PReset using PR5909 Loop Link /HART modem, or by Asset Management tool (e.g. Pactware, AMS, HART communicator).
- The 6437A can be mounted in zone 2 and zone 22 / Class I, Division 2, Groups A, B, C, D.
Data sheet & Manuals
Data sheet
- 6437A.pdf
- Latest version
Manuals
- 6437V105_UK.pdf
- 6437V104_UK.pdf
- 6437V103_UK.pdf
- 6437V102_UK.pdf
- 6437V101_UK.pdf
- 6437V100_UK.pdf
- Previous versions
- Latest version
Manuals in Russian
- 6437V105_RU.pdf
- 6437V104_RU.pdf
- 6437V103_RU.pdf
- 6437V102_RU.pdf
- 6437V101_RU.pdf
- 6437V100_RU.pdf
- Previous versions
- Latest version
Safety manual (SIL)
Approvals & Certificates
ATEX certificate
- 6437A_18ATEX0135X_issue5.pdf
- 6437A_18ATEX0135X_issue4.pdf
- 6437A_18ATEX0135X_issue3.pdf
- 6437A_18ATEX0135X_issue2.pdf
- 6437A_18ATEX0135X_issue1.pdf
- 6437A_18ATEX0135X_issue0.pdf
- 6437A_18ATEX0101_issue1_PR.pdf
- Previous versions
- Latest version
IECEx certificate
- 6437AIEC_160029X_issue7.pdf
- 6437AIEC_160029X_issue6.pdf
- 6437AIEC_160029X_issue5.pdf
- 6437AIEC_160029X_issue4.pdf
- 6437AIEC_160029X_issue3.pdf
- 6437AIEC_160029X_issue2.pdf
- 6437AIEC_160029X_issue1.pdf
- Previous versions
- Latest version
CSA certificate
- 54xx_64xx_CSA_70066266.pdf
- Latest version
FM certificate
- 54xx_64xx_FM16US0287X_FM16CA0146X.pdf
- Latest version
INMETRO certificate
- INMETRO_54xx_64xx_230002X_issue1.pdf
- INMETRO_54xx_64xx_230002X_issue0.pdf
- INMETRO_54xx_64xx_160008X_issue3.pdf
- INMETRO_54xx_64xx_160008X_issue2.pdf
- Previous versions
- Latest version
NEPSI certificate
- 643x_NEPSI_GYJ231253X.pdf
- 643x_NEPSI_GYJ181057X.pdf
- Previous versions
- Latest version
SIL certificate
- 5437_6437_V01xxxx_SIL.pdf
- Latest version
DNV marine certificate
- DNV_EU_RO_5437_6437.pdf
- Latest version
EAC declaration
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Latest version
EAC declaration
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Belarus
- MPA_Belarus.pdf
- Latest version
Metrology Pattern Approval (MPA), Kazakhstan
- MPA_Kazakhstan.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 6437DoC_EU_101_UK.pdf
- 6437DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 6437DoC_UKCA_100_UK.pdf
- Latest version
CCC statement
- 5000_6000_series_CCC_statement.pdf
- Latest version
Assessment report
- AssessmentReport_5437_6437_V2R2.pdf
- Latest version
FMEDA report
- FMEDA_PR_6437_V1R1.pdf
- Latest version
ISO 13849 declaration
- 5437xxSx_6437xxSx_ISO_13849_declaration.pdf
- Latest version
Field device specification
- 6437_FieldDeviceSpecification_V6R0.pdf
- Latest version
DTM certificate
- 5437_6437_DTM_certificate.pdf
- Latest version
HART certificate
- 5437_6437_HART_7_certificate.pdf
- Latest version
EAC LVD declaration
- 5437_6437_EMC_data.pdf
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Safety note
- SN6437-105-2605.pdf
- SN6437-104-2508.pdf
- SN6437-103-2240.pdf
- SN6437-102-2114.pdf
- SN6437-101-2106.pdf
- SN6437-100-1924.pdf
- Previous versions
- Latest version
Download Software
View variants
Environmental Conditions
| Operating temperature |
|
| Storage temperature | |
| Calibration temperature | |
Mechanical specifications
|
|
|
|
|
|