Valve controller
PR 2224
- Front-programmable
- mA, V, and Ω programmable input
- Ramp times, jump values, reversal, chopper frequency, and deadband
- 3-digit LED display shows I-valve % value
- 1 or 2 channels
Advanced features
- Multifunction user interface consisting of three pushbuttons and a 3-digit LED display.
- All parameters are protected against unauthorized changes with a password.
Application
- Control and regulation of single- or double-coil hydraulic and pneumatic proportional valves used for accurate oil flow regulation, linear soft acceleration and deceleration, modulated output signal, and programmable deadband.
- Is highly suitable for joystick regulation of A/B movements.
- Where changes to A and B need to be selected directly or according to the value of an input signal.
Technical characteristics
- During operation the display shows the present output signal as a % of the I valve.
- Programmable current or voltage input for standard signals acc. to order schedule, joystick / potentiometer or a special non-programmable input.
- Digital inputs for external control functions.
- A pulsating current output prevents the connected valve from sticking.
- Optional programming of the modulation frequency (PWM) between 8 and 400 Hz.
- Multiple adjustable parameters such as output currents, ramp times, jump values, chopper frequency, reversal, deadband, and ON/OFF functions.
- Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.
Data sheet & Manuals
Data sheet
- 2224.pdf
- Latest version
Manuals
- 2224V105_UK.pdf
- 2224V104_UK.pdf
- 2224V103_UK.pdf
- 2224V102.pdf
- 2224V101.pdf
- Previous versions
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 2224DoC_EU_102_UK.pdf
- 2224DoC_EU_101_UK.pdf
- 2224DoC_EU_100_UK.pdf
- Previous versions
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Safety note
Approvals & Certificates
EAC declaration
- EAC-Declaration.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
View variants
Environmental Conditions
| Operating temperature | -20°C to +60°C |
| Relative humidity | < 95% RH (non-cond.) |
| Protection degree | IP50 |
Mechanical specifications
| Dimensions (HxWxD) | 80.5 x 35.5 x 84.5 mm (D is without pins) |
| Weight approx. | 130 g |
Common specifications
Supply |
|
| Supply voltage (nom. 12 V / 24 V) | 9.6...28.8 VDC |
| Internal power dissipation |
2 W / 24 V
1,8 W / 12 V |
| Programming | Front-programmable |
| Updating time | 30 ms |
| Temperature coefficient | 0.01%/°C |
| Accuracy | Better than 0.2% of selected range |
| Linearity error | 0.2% |
| EMC immunity influence | < 2% of span |
Input specifications
Current input |
|
| Measurement range |
0...20 mA
4...20 mA |
| Input resistance | 50 Ω + PTC (54 Ω) |
Voltage input |
|
| Measurement range | 0/0.2...1 V and 0/2...10 V |
| Input resistance | 10 MΩ |
Potentiometer input |
|
| Potentiometer min....max. | 0...10 V or ±10 V / 10 kΩ |
| Operation / shutdown | PNP / 2.2 kΩ, 12 / 24 V |
| Imax.1 & Imax.2 | PNP / 2.2 kΩ, 12 / 24 V |
| A / B channel | PNP / 2.2 kΩ, 12 / 24 V |
| Deadband | 0...99.9% of input span |
Output specifications
| Output voltage | Supply voltage-0.5 V (max.) |
| Output current | 3000 mA mean |
| Current peak | 7 A |
| Reference voltage |
10 VDC (A valve)
±10 VDC (A & B valve) |
| Ramp up & down | Time 0...10.0 s |
| PWM frequency | 8...400 Hz in steps of 1 Hz |
| of span | = of the presently selected range |
Observed authority requirements
| EMC | 2014/30/EU |
| RoHS | 2011/65/EU |
| EAC | TR-CU 020/2011 |