PROFIBUS PA temperature transmitter
PR 5450A
- PROFIBUS PA profile 4.0
- RTD, TC, potentiometer, linear resistance and bipolar mV input
- Single or true dual inputs with sensor redundancy and drift detection
- Easy Ex i deployment with conformity to FISCO IEC 60079-27
- Accuracy from 0.04°C
- 2.5 kVAC galvanic isolation
Application
- Temperature measurement of a wide range of TC and RTD types.
- Conversion of wide span linear resistance and potentiometer inputs to PROFIBUS.
- Conversion of bipolar mV signals to PROFIBUS.
- Integration into asset management schemes.
- Critical applications requiring superior accuracy and/or sensor redundancy and drift detection.
Technical characteristics
- True dual input transmitter. High density 7-terminal design accepts the widest range of dual input combinations.
- Sensor drift detection - alerts when sensor differential exceeds user-defined limits, for maintenance optimization.
- Variable mapping for process data such as average, differential and min./max. tracking.
- Groundbreaking digital and analog signal accuracy over full input span and ambient conditions.
- Extensive sensor matching including Callendar Van Dusen and custom linearizations.
- Programmable input limits with runtime metering ensure maximum process traceability and sensor out of range protection.
- Meets NAMUR NE21, NE44, NE89 and NE107 compliant diagnostics information.
Programming
- PROFIBUS PA functions and device-specific parameters are configured via fieldbus communication and the associated DD / DTM / GSD device drivers.
Mounting / installation
- For DIN form B sensor head mounting.
- Mounting in zone 2 and zone 22 / Class I, Division 2, Groups A, B, C, D.
Data sheet & Manuals
Data sheet
- 5450A.pdf
- Latest version
Manuals
- 5450V100_EN.pdf
- Latest version
Manuals in Russian
- 5450V100_RU.pdf
- Latest version
Approvals & Certificates
ATEX certificate
- 5450A_24ATEX0007X_issue0.pdf
- Latest version
IECEx certificate
- 5450AIEC_240005X_issue0.pdf
- Latest version
ATEX test report
- ATEX_test_report_DEK_24.0005_000.pdf
- Latest version
CSA certificate
- 5450_CSA_80210307.pdf
- Latest version
FM certificate
- 5450_FM25US0051X_FM25CA0022X.pdf
- Latest version
INMETRO certificate
- 5450_INMETRO_250004X_issue0.pdf
- Latest version
NEPSI certificate
- 5450_NEPSI_GYJ261016X.pdf
- Latest version
EAC declaration
- EAC_EMC_declaration_5131B_5202B_5450.pdf
- Latest version
EAC declaration
- EAC_Ex_5131B_5202B_5450.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 5450DoC_EU_100_UK.pdf
- Latest version
EAC LVD declaration
- 5450_EMC_data.pdf
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Download Software
View variants
Environmental Conditions
| Operating temperature | |
| Storage temperature | |
| Calibration temperature | |
Mechanical specifications
|
|
|