Dual switchmode power supply
2223
- 24 / 115 / 230 VAC supply voltage
- 3.75 kVAC isolation
- 2 adjustable 5...24 VDC outputs
- Output: ±5...24 VDC, 10...48 VDC
- Short-circuit protection
- Thermal protection against overload
Advanced features
- The power supply is based on switch mode technology to achieve a high efficiency.
- The outputs are adjustable by 2 front potentiometers in the ranges 5...24 VDC.
Application
- Supply for small measuring systems that demand 2 stabilized voltages.
- Either as a combination of positive and negative voltages, or as 2 separate supplies as required.
- The two supplies are galvanically separated with 500 VAC test voltage and can be connected in series or used as two independent supplies with or without common gnd.
- Separation of circuits in safety installations according to PELV/SELV.
- Galvanic isolation between the primary and the secondary voltage is achieved through the double-isolated safety transformer.
Technical characteristics
- Two green LEDs, Power ON 1 and Power ON 2, indicate active outputs.
- By connecting the two outputs in series, 10...48 VDC or ±5...24 VDC can be achieved.
- The input circuit is protected with a bimetal thermal fuse.
- DC output short circuit protection with current limiter.
- Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate use with PR’s 7023 adaptor and 7024 mounting keying.
Data sheet & Manuals
Supplementary documentation
EU Declaration of Conformity
- 2223DoC_EU_102_UK.pdf
- 2223DoC_EU_101_UK.pdf
- 2223DoC_EU_100_UK.pdf
- Previous versions
- Latest version
Safety note
Safety note
- SN2200-2_102_1949.pdf
- SN2200-2_101_1613.pdf
- SN2200-2_100_1035.pdf
- Previous versions
- Latest version
Approvals & Certificates
EAC declaration
- EAC-Declaration.pdf
- Latest version
EAC LVD declaration
- EAC_LVD-Declaration.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Environmental Conditions
Operating temperature | -20°C to +60°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP30 |
Mechanical specifications
Dimensions (HxWxD) | 80.5 x 35.5 x 84.5 mm (D is without pins) |
Weight approx. | 400 g |
Common specifications
Supply |
|
Internal power dissipation | 4 W |
Isolation voltage |
|
Isolation voltage, test / working | 3.75 kVAC / 250 VAC |
Isolation output 1 / 2, test / working | 500 VAC / 50 VAC (75 VDC) |
PELV/SELV | IEC 61140 |
Effect of supply voltage change | < ±30 mV (±10%) |
Transformer | EN 60742 |
Transient stability (10%-max. load) | < 250 mV |
Temperature coefficient | 0.05% / °C |
EMC immunity influence | < ±0.5% |
Input specifications
Supply voltage |
21.6...26.4 VAC
103.5...126.5 VAC 207...253 VAC |
Frequency | 50...60 Hz |
Output specifications
Current output |
|
Current limit | Typ. 100 mA (short circuit) |
Output voltage | 4.75...25.2 VDC |
Output power | Max. 7.5 W (total) |
Output current, per channel |
0.5 A / 5 VDC (2.5 W)
0.37 A / 12 VDC (4.5 W) 0.30 A / 15 VDC (4.5 W) 0.18 A / 24 VDC (4.3 W) |
Load effect (10%-max. load) | < 1.5% / A |
Output ripple | < 20 mVRMS |
Observed authority requirements
EMC | 2014/30/EU |
LVD | 2014/35/EU |
RoHS | 2011/65/EU |
EAC | TR-CU 020/2011 |
EAC LVD | TR-CU 004/2011 |