5223A
 

Programmable f/I-f/f converter

 

5223A

 

  • Pulse calculator
  • Frequency generator
  • Galvanic isolation
  • Analog current and voltage output
  • PNP / NPN output, optional relays
  • Universal supply
  1. Översikt + -

  2. Tekniska data + -

  3. Tillbehör + -


Advanced features

  • The 5223 transmitter can be configured with a standard PC and the Loop Link communications unit, or delivered fully configured.

Application

  • The f/I function performs frequency to current and voltage conversion.
  • The f/f function can be used for pulse division or multiplication and as a buffer collecting fast pulse trains.
  • A scale factor may be entered in all functions. Using both digital inputs, pulse addition or subtraction are possible.
  • The frequency generator function is used as e.g. a time base or clock generator.
  • Input and supply polarity reversal protection.
  • Current and voltage output signals galvanically separated from the supply and the inputs.
  • Programmable digital outputs including NPN, PNP or relay options.

Technical characteristics

  • 5 front LEDs, indicating f1 and f2 active inputs (not NPN), Dig.out.1 and 2 active outputs, and a programmable error signal.
  • Analog current output can be configured to any current within 0...20 mA range.
  • Voltage output range is selectable between 0...10 VDC and 0...1 VDC by use of internal jumpers.
  • Input range:

    Frequency: 0...20,000 Hz

    Sensor types: NAMUR, tacho, NPN, PNP, TTL, S0

  • Output range:

    Current and voltage output: 0...20 mA / 0...10 V

    Relay outputs: 0...20 Hz

    NPN and PNP output as f/f: 0...1000 Hz

    NPN and PNP output as generator: 0...20,000 Hz

Datablad & Manualer


Datablad

Manualer

Manualer på ryska

Kompletterande dokumentation


EU försäkran om överensstämmelse

Säkerhetsanvisningar


Säkerhetsanvisningar

Godkännanden och certifikat


EAC-försäkran

EAC LVD-försäkran

Metrology Pattern Approval (MPA)

Environmental Conditions

Operating temperature -20°C to +60°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP20

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 130 mm
Weight approx. 240 g
DIN rail type DIN 46277
Wire size 1 x 2.5 mm2 stranded wire
Screw terminal torque 0.5 Nm

Common specifications

Supply

Supply voltage, universal 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC
Fuse 400 mA SB / 250 VAC
Max. required power 3.5 W
Internal power dissipation 3 W

Isolation voltage

Isolation voltage, test / working 3.75 kVAC / 250 VAC
Power-up delay 0...999 s
Warm-up time 1 min.
Programming Loop Link
Signal / noise ratio Min. 60 dB
Response time, analog < 60 ms + period
Response time, digital output < 50 ms + period
Signal dynamics, output 16 bit
Effect of supply voltage change < 0.005% of span / VDC
Auxiliary voltage: NAMUR supply 8.3 VDC ±0.5 VDC / 8 mA
S0 supply 17 VDC / 20 mA
NPN / PNP supply 17 VDC / 20 mA
Special supply (programmable) 5...17 VDC / 20 mA
Temperature coefficient < ±0.01% of span / °C
Linearity error < 0.1% of span
EMC immunity influence < ±0.5%

Input specifications

Common input specifications

Max. offset 90% of selected max. frequency
Measurement range 0...20 kHz
Min. measurement range 0.001 Hz
Max. frequency, with input filter ON 50 Hz
Min. period time with input filter ON 20 ms
Input types NAMUR acc. to DIN 19234 Tacho
NPN / PNP
2-phase encoder
TTL
S0 acc. to DIN 43864

Output specifications

Common output specifications

Updating time 20 ms

Current output

Signal range 0...20 mA
Min. signal range 5 mA
Load (@ current output) ≤ 600 Ω
Load stability ≤ 0.01% of span / 100 Ω
Current limit < 23 mA

Voltage output

Signal range 0...10 VDC
Min. signal range 250 mV
Load (@ voltage output) ≥ 500 kΩ

Relay output

Max. switching frequency 20 Hz
Max. voltage 250 VRMS
Max. current 2 AAC
Max. AC power 100 VA
Max. load at 24 VDC 1 A
Other output types Active outputs (NPN / PNP) f/f converter output
Frequency generator
of span = of the presently selected range

Observed authority requirements

EMC 2014/30/EU
LVD 2014/35/EU
RoHS 2011/65/EU
EAC TR-CU 020/2011
 

Är denna information användbar?

 

Betygsätt oss

Din förfrågan har skickats. 0 artiklar på din lista
Er kontaktinformation
Vänligen ange ditt förnamn
Vänligen ange ditt efternamn
Vänligen ange en giltig e-postadress
Vänligen ange ett giltigt telefonnummer. Använd endast siffror.
Vänligen ange din jobbtitel
Vänligen ange ditt företagsnamn
Vänligen ange din företagsadress
Vänligen ange ett giltigt postnummer
Vänligen ange en stad
Välj land
Läs och godkänn PR electronics sekretesspolicy.
Du har inte lagt till några produkter i din offertlista
När du surfar på webbplatsen kan du lägga till produkter i en offertlista genom att helt enkelt klicka på "Lägg till offertlistan" på de enskilda produktsidorna. När alla relevanta produkter ingår, skicka listan till oss så får du en offert inom 24 timmar. Om du inte skickar listan kommer den att finnas tillgänglig på webbplatsen i 21 dagar. Vi hoppas att du finner funktionaliteten användbar.
Tack för att du begär en offert. Vi återkommer via telefon eller e-post inom 24 timmar.

Behövs hjälp?

Om du behöver support är du alltid välkommen att kontakta oss

Håll dig uppdaterad!

Registrera dig här för att få vårt nyhetsbrev