2-wire transmitter with HART protocol
5337A
- RTD, TC, Ohm, and bipolar mV input
- 2 analog inputs and 5 device variables with status available
- HART protocol revision selectable from HART 5 or HART 7
- Hardware assessed for use in SIL applications
- Mounting in Safe area or Zone 2/22
Application
- Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
- HART communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
- Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
- Amplification of bipolar mV signals to standard 4...20 mA current signals.
- Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.
Technical characteristics
- HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
- The HART 7 protocol offers:
∙ Long Tag numbers of up to 32 characters.
∙ Enhanced Burst Mode and Event notification with time stamping.
∙ Device variable and status mapping to any dynamic variable PV, SV, TV or QV.
∙ Process signal trend measurement with logs and summary data.
∙ Automatic event notification with time stamps.
∙ Command aggregation for higher communication efficiency. - 5337A is designed according to strict safety requirements and is therefore suitable for applications in SIL installations.
- Continuous check of vital stored data.
- Meeting the NAMUR NE21 recommendations, the 5337 HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the 5337 meets NAMUR NE43 and NE89 recommendations.
Mounting / installation
- For DIN form B sensor head or DIN rail mounting via the PR fitting type 8421.
- Configuration via standard HART communication interfaces or by PR 5909 Loop Link.
Datablad & Manualer
Datablad
- 5337A.pdf
- Senaste versionen
Manualer
- 5337V107_UK.pdf
- 5337V106_UK.pdf
- 5337V105_UK.pdf
- 5337V104_UK.pdf
- 5337V103_UK.pdf
- 5337V102_UK.pdf
- 5337V100_UK.pdf
- Tidigare versioner
- Senaste versionen
Manualer på ryska
- 5337V107_RU.pdf
- 5337V106_RU.pdf
- 5337V105_RU.pdf
- 5337V104_RU.pdf
- 5337V103_RU.pdf
- 5337V102_RU.pdf
- Tidigare versioner
- Senaste versionen
Godkännanden och certifikat
ATEX-certifikat
- 5337A_20ATEX0109X_issue0.pdf
- 5337A_03ATEX1508X_issue06.pdf
- 5337A_03ATEX1508X_issue05.pdf
- 5337A_03ATEX1508X_issue04.pdf
- Tidigare versioner
- Senaste versionen
IECEx-certifikat
- 5337AIEC_200063X_issue0.pdf
- 5337AIEC_100083X_issue04.pdf
- 5337AIEC_100083X_issue03.pdf
- 5337AIEC_100083X_issue02.pdf
- 5337AIEC_100083X_issue01.pdf
- Tidigare versioner
- Senaste versionen
CSA-certifikat
- 533x_633x_CSA.pdf
- Senaste versionen
INMETRO-certifikat
- INMETRO_5335_5337_180002x_issue1.pdf
- INMETRO_5335_5337_180002x_issue0.pdf
- Tidigare versioner
- Senaste versionen
DNV-certifikat
- DNV_2231_41xx_51xx_53xx.pdf
- Senaste versionen
EAC-försäkran
- EAC-Declaration.pdf
- Senaste versionen
EAC Ex-certifikat
- EAC_Ex.pdf
- Senaste versionen
Metrology Pattern Approval (MPA), Belarus
- MPA_Belarus.pdf
- Senaste versionen
Metrology Pattern Approval (MPA), Kazakhstan
- MPA_Kazakhstan.pdf
- Senaste versionen
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Senaste versionen
Kompletterande dokumentation
EU försäkran om överensstämmelse
- 5337DoC_EU_106_UK.pdf
- 5337DoC_EU_105_UK.pdf
- 5337DoC_EU_104_UK.pdf
- 5337DoC_EU_103_UK.pdf
- 5337DoC_EU_102_UK.pdf
- 5337DoC_EU_101_UK.pdf
- 5337DoC_EU_100_UK.pdf
- Tidigare versioner
- Senaste versionen
CCC-uttalande
- 5000_6000_series_CCC_statement.pdf
- Senaste versionen
FMEDA-rapport
- FMEDA_5337_R026V3R2.pdf
- FMEDA_5337_R026V3R1.pdf
- FMEDA_5337_R026V1R0.pdf
- Tidigare versioner
- Senaste versionen
SIL-försäkran
- 5335_6335_5337_6337_7501_SIL1_declaration_Potmeter_V2.pdf
- 5335_6335_5337_6337_7501_SIL2_declaration_V2.pdf
- Tidigare versioner
- Senaste versionen
HART-certifikat
- 5337_HART.pdf
- Senaste versionen
Säkerhetsanvisningar
Säkerhetsanvisningar
- SN5300-3_113_2202.pdf
- SN5300-3_112_2139.pdf
- SN5300-3_111_2016.pdf
- SN5300-3_110_1911.pdf
- SN5300-3_109_1838.pdf
- SN5300-3_108_1803.pdf
- SN5300-3_107_1616.pdf
- SN5300_106_1509.pdf
- Tidigare versioner
- Senaste versionen
Environmental Conditions
Operating temperature | -40°C to +85°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree (encl./terminal) | IP68 / IP00 |
Mechanical specifications
Dimensions | Ø 44 x 20.2 mm |
Weight approx. | 50 g |
Wire size | 1 x 1.5 mm2 stranded wire |
Screw terminal torque | 0.4 Nm |
Vibration | IEC 60068-2-6 |
2...25 Hz | ±1.6 mm |
25...100 Hz | ±4 g |
Common specifications
Supply |
|
Supply voltage | 8.0...35 VDC |
Isolation voltage |
|
Isolation voltage, test / working | 1.5 kVAC / 50 VAC |
Response time |
|
Response time (programmable) | 1...60 s |
Voltage drop | 8.0 VDC |
Signal / noise ratio | > 60 dB |
Programming | Loop Link & HART |
Accuracy | Better than 0.05% of selected range |
Signal dynamics, input | 22 bit |
Signal dynamics, output | 16 bit |
EMC immunity influence | < ±0.1% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Common input specifications |
|
Max. offset | 50% of selected max. value |
RTD input |
|
RTD type | Pt50/100/200/500/1000; Ni50/100/120/1000 |
Cable resistance per wire | 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy) |
Sensor current | Nom. 0.2 mA |
TC input |
|
Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
Cold junction compensation (CJC) | Constant, internal or external via a Pt100 or Ni100 sensor |
Voltage input |
|
Measurement range | -800...+800 mV |
Min. measurement range (span) | 2.5 mV |
Input resistance | 10 MΩ |
Output specifications
Current output |
|
Signal range | 4…20 mA |
Min. signal range | 16 mA |
Load (@ current output) | ≤ (Vsupply - 8) / 0.023 [Ω] |
Sensor error indication | Programmable 3.5…23 mA |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Common output specifications |
|
Updating time | 440 ms |
HART protocol revisions | HART 7 and HART 5 |
I.S. / Ex marking
ATEX | II 3 G Ex nA [ic] IIC T6...T4 Gc, II 3 G Ex ex [ic] IIC T6...T4 Gc, II 3 D Ex ic IIIC Dc |
IECEx | Ex nA [ic] IIC T6…T4 Gc, Ex ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc |
CSA | Cl. I, Div. 2, Gp. A, B, C, D T6...T4, Ex nA[ic] IIC T6…T4 Gc |
INMETRO | Ex nA [ic] IIC T6...T4 Gc, Ex ic IIC T6...T4 Gc, Ex ic IIIC Dc |
Observed authority requirements
EMC | 2014/30/EU |
ATEX | 2014/34/EU |
RoHS | 2011/65/EU |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals
DNV Marine | TAA0000101 |
ATEX | DEKRA 20ATEX0109X |
IECEx | DEK 20.0063X |
CSA | 1125003 |
INMETRO | DEKRA 18.0002X |
EAC Ex | RU C-DK.HA65.B.00355/19 |
SIL | Hardware assessed for use in SIL applications |
Need support to select the right product for your application?
Our sales engineers are ready to help specify the right device to meet your needs.
Reach out by phone to get in touch with us straight away – or use the contact form or quick quote function to send your RFQ directly from the website. You’ll get a response within 24 hours on normal business days.
You can expect to get a confirmed delivery date via email within 2 days after we have received your order.
As soon as your package leaves our warehouse, you’ll receive tracking details via email. And if you have any questions along the way we’re just a phone call or email away.
![]() |
State-of-the-art manufacturing Our 8,500 sqm integrated and automated manufacturing campus in Denmark covers the entire value-chain from design and development to manufacturing. It allows us to design and optimize for testing and manufacturing thereby constantly driving quality up and costs down. |
![]() |
Dedicated Presale / Aftersales
|
![]() |
Product reliability |
![]() |
Product deployment
|
![]() |
Smart products
Check out our range of communication interfaces
|