Power connector unit
3405
- Slimline housing of 6,1 mm
- Supplies DIN rail from supply terminals
- Can pass up to 2.5 A
- Up to 100 units can be powered
Applications
- Power can be connected to the DIN rail from supply terminals.
- Alternatively a powered DIN rail can supply power to the terminals.
- Installation in ATEX Ex zone 2 / IECEx zone 2 / FM division 2.
- Suitable for environments with high vibration stress, e.g. ships.
Technical characteristics
- 3405 can pass up to 2.5 A
- With 3405, up to 92 units can be powered (depending on the PR product type).
Datablad & Manualer
Godkännanden och certifikat
ATEX-certifikat
- 3405_issue11.pdf
- Senaste versionen
IECEx-certifikat
- 3405IEC_issue 10.pdf
- Senaste versionen
UKEX Certificate
- 3405UKEX_Issue 0.pdf
- Senaste versionen
CCC certifikat
- 3000_series_CCC_2020_12.pdf
- Senaste versionen
FM-certifikat
- 3xxx_FM17CA0003X_US0004X.pdf
- 3xxx_FM_3041043_C.pdf
- Tidigare versioner
- Senaste versionen
UL-certifikat
- 3103-09_3117-18_3405.pdf
- Senaste versionen
DNV-certifikat
- DNV_GL_3xxx_TAA00001RW.pdf
- Senaste versionen
EAC-försäkran
- EAC-Declaration.pdf
- Senaste versionen
EAC Ex-certifikat
- EAC_Ex.pdf
- Senaste versionen
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Senaste versionen
Kompletterande dokumentation
EU försäkran om överensstämmelse
- 3405DoC_EU_104_UK.pdf
- 3405DoC_EU_103_UK.pdf
- 3405DoC_EU_102_UK.pdf
- 3405DoC_EU_101_UK.pdf
- 3405DoC_EU_100_UK.pdf
- Tidigare versioner
- Senaste versionen
UKCA försäkran om överensstämmelse
- 3405DoC_UKCA_100_UK.pdf
- Senaste versionen
Säkerhetsanvisningar
Säkerhetsanvisningar
- SN3000_1_117_2204.pdf
- SN3000_115_2102.pdf
- SN3000_114_1939.pdf
- SN3000_113_1741.pdf
- SN3000_112_1714.pdf
- SN3000_111_1703.pdf
- SN3000_110_1637.pdf
- SN3000_109_1617.pdf
- Tidigare versioner
- Senaste versionen
Environmental Conditions
Operating temperature | -25°C to +70°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications
Dimensions (HxWxD) | 113 x 6.1 x 115 mm |
Weight approx. | 65 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13...2.5 mm2 / AWG 26...12 stranded wire |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2...25 Hz | ±1.6 mm |
25...100 Hz | ±4 g |
Common specifications
Supply |
|
Supply voltage | 16.8...31.2 VDC |
Internal power dissipation | 0.25 W (max.) |
Required external fuse | 2.5 A |
I.S. / Ex marking
ATEX | II 3 G Ex ec IIC T4 Gc |
IECEx | Ex ec IIC T4 Gc |
FM, US | Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4 |
FM, CA | Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4 |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
LVD | 2014/35/EU & UK SI 2016/1101 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals
ATEX | KEMA 10ATEX0147 X |
IECEx | KEM 10.0068X |
UKEX | DEKRA 21UKEX0055X |
c FM us | FM17US0004X / FM17CA0003X |
c UL us, UL 61010-1 | E314307 |
EAC Ex | RU C-DK.HA65.B.00355/19 |
DNV Marine | TAA00001RW |
CCC | 2020322310003554 |