2-wire programmable RTD transmitter
5332A
- RTD or Ohm input
- Accuracy: Better than 0.05% of selected range
- Programmable sensor error value
- For DIN form B sensor head mounting
Application
- Linearized temperature measurement with Pt100...Pt1000 or Ni100...Ni1000 sensor.
- Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level sensors.
Technical characteristics
- Within a few seconds the user can program PR5332A to measure temperatures within all ranges defined by the norms.
- Dedicated programmable non-isolated 4-wire RTD transmitter.
- RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection.
- Continuous check of vital stored data for safety reasons.
Mounting / installation
- For DIN form B sensor head or DIN rail mounting with the PR fitting type 8421.
Data sheet & Manuals
Data sheet
- 5332A.pdf
- Latest version
Manuals
- 5332V103_UK.pdf
- 5332V102_UK.pdf
- 5332V101_UK.pdf
- 5332V100_UK.pdf
- Previous versions
- Latest version
Manuals in Russian
- 5332V103_RU.pdf
- 5332V102_RU.pdf
- 5332V101_RU.pdf
- 5332V100_RU.pdf
- Previous versions
- Latest version
Approvals & Certificates
ATEX certificate
- 5332A_20ATEX0096X_issue0.pdf
- 5332A_10ATEX0002X_issue03.pdf
- Previous versions
- Latest version
IECEx certificate
- 5332AIEC_200059X_issue0.pdf
- 5332AIEC_130035X_issue1.pdf
- Previous versions
- Latest version
INMETRO certificate
- INMETRO_5331_5332_5334_160013x_issue1.pdf
- Latest version
EAC declaration
- EAC-Declaration.pdf
- Latest version
EAC Ex certificate
- EAC_Ex.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 5332DoC_EU_106_UK.pdf
- 5332DoC_EU_105_UK.pdf
- 5332DoC_EU_104_UK.pdf
- 5332DoC_EU_103_UK.pdf
- Previous versions
- Latest version
CCC statement
- 5000_6000_series_CCC_statement.pdf
- Latest version
Safety note
Safety note
- SN5332_103_2202.pdf
- SN5332_102_2122.pdf
- SN5332_101_2007.pdf
- SN5332_100_1848.pdf
- Previous versions
- Latest version
Environmental Conditions
Operating temperature | -40°C to +85°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree (encl./terminal) | IP68 / IP00 |
Mechanical specifications
Dimensions | Ø 44 x 20.2 mm |
Weight approx. | 50 g |
Wire size | 1 x 1.5 mm2 stranded wire |
Screw terminal torque | 0.4 Nm |
Common specifications
Supply |
|
Supply voltage | 7.2...35 VDC |
Internal power dissipation | 25 mW…0.8 W |
Response time |
|
Response time (programmable) | 1...60 s |
Voltage drop | 7.2 VDC |
Warm-up time | 5 min. |
Programming | Loop Link |
Signal / noise ratio | Min. 60 dB |
EEprom error check | < 3.5 s |
Accuracy | Better than 0.05% of selected range |
Signal dynamics, input | 20 bit |
Signal dynamics, output | 16 bit |
Effect of supply voltage change | < 0.005% of span / VDC |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Common input specifications |
|
Max. offset | 50% of selected max. value |
RTD input |
|
RTD type | Pt100, Ni100, lin. R |
Cable resistance per wire | 5 Ω (max.) |
Sensor current | Nom. 0.2 mA |
Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
Sensor error detection | Yes |
Linear resistance input |
|
Linear resistance min....max. | 0 Ω...5000 Ω |
Output specifications
Common output specifications |
|
Updating time | 440 ms |
Current output |
|
Signal range | 4…20 mA |
Min. signal range | 16 mA |
Load (@ current output) | ≤ (Vsupply - 7.2) / 0.023 [Ω] |
Load stability | ≤ 0.01% of span / 100 Ω |
Sensor error indication | Programmable 3.5…23 mA |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
of span | = of the presently selected range |
I.S. / Ex marking
ATEX | II 3 G Ex nA [ic] IIC T6...T4 Gc, II 3 G Ex ex [ic] IIC T6...T4 Gc, II 3 D Ex ic IIIC Dc |
IECEx | Ex nA [ic] IIC T6…T4 Gc, Ex ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc |
Observed authority requirements
Directives |
|
EMC | 2014/30/EU |
ATEX | 2014/34/EU |
RoHS | 2011/65/EU |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals
ATEX | DEKRA 20ATEX0096X |
IECEx | DEK 20.0059 X |
CSA | 1125003 |
INMETRO | DEKRA 16.0013 X |
EAC Ex | RU C-DK.HA65.B.00355/19 |

7400
Pt100 temperature sensor
7430B
Pt100 cable sensor
7430C
Pt100 cable sensor
7440
Thermowell for PR 7400 Pt100 sensor
5909
Loop Link communications interface
7007
2-digit digital potentiometer
7008
3-digit digital potentiometer
7010
10-turn potentiometer, 20 kΩ
7011
Dial for 10-turn potentiometer
7012
1-turn potentiometer, 1 kΩ
7020
Knob for 1-turn potentiometer
7020A
Knob for 10-turn potentiometer
7028
10-turn potentiometer, 2 kΩ