Ex solenoid / alarm driver
5203B
- 1- or 2-channel version
- Solenoid driver for I.S. area
- 3- / 5-port 3.75 kVAC galvanic isolation
- Digitally controlled voltage supply for I.S. area
- Universal supply by AC or DC
Application
- Driver with safety barrier for the control of ON / OFF solenoids mounted in hazardous area.
- Driver with safety barrier for the supply of LEDs and acoustic alarms mounted in hazardous area.
- Voltage supply with ON / OFF control of other equipment.
Technical characteristics
- PR5203B has a digital input per channel for the control of the I.S. output voltage.
- Supply, inputs, and outputs are floating and galvanically separated.
Mounting / installation
- Mounted vertically or horizontally on a DIN rail. By way of the 2-channel version up to 84 channels per meter can be mounted.
Data sheet & Manuals
Data sheet
- 5203B.pdf
- Latest version
Manuals
- 5203BV105_UK.pdf
- 5203BV104.pdf
- Previous versions
- Latest version
Manuals in Russian
- 5203BV105_RU.pdf
- Latest version
Approvals & Certificates
Ex certificate
- 5203B.pdf
- Latest version
UL certificate
- 5203B_UL.pdf
- Latest version
EAC declaration
- EAC-Declaration.pdf
- Latest version
EAC Ex certificate
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 5203DoC_EU_102_UK.pdf
- 5203DoC_EU_101_UK.pdf
- 5203DoC_EU_100_UK.pdf
- Previous versions
- Latest version
Safety note
Safety note
- SN5000-3_103_1933.pdf
- SN5000-3_102_1613.pdf
- SN5000_101_1450.pdf
- Previous versions
- Latest version
Environmental Conditions
Operating temperature | -20°C to +60°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 130 mm |
Weight approx. | 230 g |
Wire size | 1 x 2.5 mm2 stranded wire |
Screw terminal torque | 0.5 Nm |
Common specifications
Supply |
|
Supply voltage, universal | 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC |
Fuse | 400 mA SB / 250 VAC |
Max. required power | ≤ 4 W (2 channels) |
Internal power dissipation | ≤ 2 W (2 channels) |
Isolation voltage |
|
Isolation voltage, test / working | 3.75 kVAC / 250 VAC |
PELV/SELV | IEC 61140 |
Max. frequency | 20 Hz |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
NPN and mechanical switch |
|
Trig level LOW | ≤ 4.0 VDC |
Trig level HIGH | ≥ 7.0 VDC |
Max. external voltage | 28 VDC |
Input impedance | 3.48 kΩ |
PNP |
|
Trig level LOW | ≤ 4.0 VDC |
Trig level HIGH | ≥ 7.0 VDC |
Max. external voltage | 28 VDC |
Input impedance | 3.48 kΩ |
Output specifications
Output voltage | See Ex data in manual |
Output current | See Ex data in manual |
Output ripple | < 40 mVRMS |
Observed authority requirements
EMC | 2014/30/EU |
LVD | 2014/35/EU |
EAC | TR-CU 020/2011 |
Approvals
ATEX | DEMKO 99ATEX126257, II (1) GD [EEx ia] IIC |
UL | UL 913, UL 508 |
EAC Ex | RU C-DK.HA65.B.00355/19 |