ADD TO QUOTE LIST
3109
Isolated converter / splitter
Isolation and conversion of standard DC signals
Slimline housing of 6 mm
Power supply and signal isolator for 2-wire transmitter
Splitter function: 1 in - 2 out
DIP-switch configured
Overview
+
Technical details
+
Accessories
+
Application
Isolation and conversion of standard DC signals.
Galvanic separation of analog current and voltage signals.
Elimination of ground loops and measurement of floating signals.
A competitive choice in terms of both price and technology for galvanic isolation of current and voltage signals to SCADA systems or PLC equipment.
Installation in ATEX Ex zone 2 / IECEx zone 2 / FM division 2.
Suitable for environments with high vibration stress, e.g. ships.
Technical characteristics
Easy configuration via DIP-switches.
The input is protected against overvoltage and polarity error.
Factory-calibrated measurement ranges.
Inputs and outputs are floating and galvanically separated.
Declaration of Conformity
DNV-GL marine certificate
Metrology Pattern Approval (MPA)
Environmental Conditions
Operating temperature
-25°C to +70°C
Storage temperature
-40°C to +85°C
Calibration temperature
20...28°C
Relative humidity
< 95% RH (non-cond.)
Protection degree
IP20
Installation in
Pollution degree 2 & meas. / overvoltage cat. II
Mechanical specifications
Dimensions (HxWxD)
113 x 6.1 x 115 mm
Weight approx.
70 g
DIN rail type
DIN EN 60715/35 mm
Wire size
0.13...2.5 mm2 / AWG 26...12 stranded wire
Screw terminal torque
0.5 Nm
Vibration
IEC 60068-2-6
2...25 Hz
±1.6 mm
25...100 Hz
±4 g
Common specifications
Supply voltage
16.8...31.2 VDC
Max. required power
1.20 W
Max. power dissipation
0.60 W
Isolation voltage, test / working
2.5 kVAC / 300 VAC (reinforced)
Zone 2 / Div. 2
250 VAC
Response time (0...90%, 100...10%)
< 7 ms
Programming
DIP-switches
Signal / noise ratio
> 60 dB
Cut-off frequency (3 dB)
> 100 Hz
Signal dynamics, input
Analog signal chain
Signal dynamics, output
Analog signal chain
Accuracy
Better than 0.05% of selected range
Temperature coefficient
< ±0.01% of span / °C
EMC immunity influence
< ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst
< ±1% of span
Input specifications
Measurement range
0...23 mA
Programmable measurement ranges
0...20 and 4...20 mA
Input voltage drop
< 1.5 VDC
Measurement range
0...10.25 V
0...11.5 V / 0...5.75 V
Programmable measurement ranges
0/1...5 and 0/2...10 V
Input resistance
≥ 500 kΩ
2-wire transmitter supply
> 17 V / 20 mA
Output specifications
Signal range
0...23 mA
Programmable signal ranges
0 / 4...20 mA
Load (@ current output)
≤ 300 Ω
Load stability
≤ 0.002% of span / 100 Ω
Current limit
≤ 28 mA
Signal range
0...10 VDC
Programmable signal ranges
0/1...5 and 0/2...10 V
Load (@ voltage output)
≥ 10 kΩ
of span
= of the DIP-switch selected output range
I.S. / Ex marking
ATEX
II 3 G Ex nA IIC T4 Gc
IECEx
Ex nA IIC T4 Gc
FM, US
Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4
FM, CA
Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4
Observed authority requirements
EMC
2014/30/EU
LVD
2014/35/EU
ATEX
2014/34/EU
RoHS
2011/65/EU
EAC
TR-CU 020/2011
EAC Ex
TR-CU 012/2011
Approvals
ATEX
KEMA 10ATEX0147 X
IECEx
KEM 10.0068X
c FM us
FM17US0004X / FM17CA0003X
c UL us, UL 61010-1
E314307
EAC Ex
RU C-DK.HA65.B.00355/19
DNV-GL Marine
TAA00001RW
Is this information helpful?