Signal calculator
5115A
- Redundancy measurement with 2 input signals
- Signal calculator with the four arithmetical operations
- Duplication of the input signal
- Input for RTD, Ohm, TC, mV, mA, and V
- Universal supply by AC or DC
Application
- Redundancy measurement of temperature by means of two sensors, where the secondary sensor takes over the measurement when a sensor error occurs on the primary sensor.
- Duplication of the input signal, e.g. from a temperature sensor or an analog process signal to two separate analog outputs.
- Signal calculator with four arithmetical operations: Addition, subtraction, multiplication and division.
- Example: Differential measurement:
(Input 1 * K1) - (Input 2 * K2) + K4 - Example: Average measurement:
(Input 1 * 0.5) + (Input 2 * 0.5) + K4 - Example: Different functions on the outputs:
Output 1 = input 1 - input 2, and Output 2 = input 1 + input 2 - Power supply for 2-wire transmitters.
Technical characteristics
- Within a few seconds the user can program PR5115A to a selected application using the configuration program PReset.
- A green front LED indicates normal operation, sensor error on each sensor, and functional error.
- Continuous check of vital stored data for safety reasons.
- 5-port 3.75 kVAC galvanic isolation.
Mounting / installation
- Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without any distance between neighboring units, up to 42 devices can be mounted per meter.
Data sheet & Manuals
Data sheet
- 5115A.pdf
- Latest version
Manuals
- 5115V105_UK.pdf
- 5115V104_UK.pdf
- 5115V103.pdf
- Previous versions
- Latest version
Manuals in Russian
- 5115V105_RU.pdf
- 5115V104_RU.pdf
- Previous versions
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 5115DoC_EU_103_UK.pdf
- 5115DoC_EU_102_UK.pdf
- 5115DoC_EU_101_UK.pdf
- 5115DoC_EU_100_UK.pdf
- Previous versions
- Latest version
Safety note
Safety note
- SN5000-2_109_2220.pdf
- SN5000-2_106_1825.pdf
- SN5000-2_105_1811.pdf
- SN5000-2_104_1725.pdf
- SN5000-2_103_1625.pdf
- SN5000-2_102_1613.pdf
- SN5000_101_1450.pdf
- Previous versions
- Latest version
Approvals & Certificates
DNV marine certificate
- DNV_2231_41xx_51xx_53xx.pdf
- Latest version
EAC declaration
- EAC-Declaration.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Environmental Conditions
Operating temperature | -20°C to +60°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 130 mm |
Weight approx. | 225 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13...2.08 mm2 AWG 26...14 stranded wire |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2...13.2 Hz | ±1 mm |
13.2...100 Hz | ±0.7 g |
Common specifications
Supply |
|
Supply voltage, universal | 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC |
Fuse | 400 mA SB / 250 VAC |
Max. required power | 2.1 W / 2.8 W (1 / 2 ch.) |
Max. power dissipation | 2.0 W |
Isolation voltage |
|
Isolation voltage, test / working | 3.75 kVAC / 250 VAC |
PELV/SELV | IEC 61140 |
Response time |
|
Temperature input, programmable (0...90%, 100...10%) | 400 ms...60 s |
mA / V input (programmable) | 250 ms...60 s |
Programming | Loop Link |
Signal / noise ratio | Min. 60 dB (0...100 kHz) |
Redundancy switch-over time | ≤ 400 ms |
Accuracy | Better than 0.05% of selected range |
Signal dynamics, input | 22 bit |
Signal dynamics, output | 16 bit |
Auxiliary voltages: Reference voltage | 2.5 VDC ±0.5% / 15 mA |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Common input specifications |
|
Max. offset | 50% of selected max. value |
RTD input |
|
RTD type | Pt46, Pt100, Ni100, Cu53, lin. R |
Cable resistance per wire | 10 Ω (max.) |
Sensor current | Nom. 0.2 mA |
Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
Sensor error detection | Yes |
TC input |
|
Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
Cold junction compensation (CJC) | < ±1.0°C |
Sensor error current | Nom. 30 μA |
Current input |
|
Measurement range | 0...100 mA |
Min. measurement range (span) | 4 mA |
Input resistance: Supplied unit | Nom. 10 Ω + PTC 10 Ω |
Input resistance: Non-supplied unit | RSHUNT = ∞, VDROP < 6 V |
Voltage input |
|
Measurement range | 0...250 VDC |
Min. measurement range (span) | 5 mV |
Input resistance |
Nom. 10 MΩ (≤ 2.5 VDC)
Nom. 5 MΩ (> 2.5 VDC) |
mV input |
|
Measurement range | -150...+150 mV |
Output specifications
Current output |
|
Signal range | 0...20 mA |
Min. signal range | 10 mA |
Load (@ current output) | ≤ 600 Ω |
Load stability | ≤ 0.01% of span / 100 Ω |
Current limit | ≤ 28 mA |
Sensor error indication | Programmable 0...23 mA |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Voltage output |
|
Signal range | 0...10 VDC |
Min. signal range | 500 mV |
Load (@ voltage output) | ≥ 500 kΩ |
Passive 2-wire mA output |
|
Signal range | 4...20 mA |
Load stability | ≤ 0.01% of span / 100 Ω |
Effect of external 2-wire supply voltage variation | < 0.005% of span / V |
Max. external 2-wire supply | 29 VDC |
of span | = of the presently selected range |
Observed authority requirements
EMC | 2014/30/EU |
LVD | 2014/35/EU |
RoHS | 2011/65/EU |
EAC | TR-CU 020/2011 |
Approvals
DNV Marine | TAA0000101 |

7423
Ceramic socket for Pt100 sensor
7430B
Pt100 cable sensor
7430C
Pt100 cable sensor
7440
Thermowell for PR 7400 Pt100 sensor
5909
Loop Link communications interface
5910
CJC connector
5913
CJC connector
7007
2-digit digital potentiometer
7008
3-digit digital potentiometer
7009
10-turn potentiometer, 200 Ω
7010
10-turn potentiometer, 20 kΩ
7011
Dial for 10-turn potentiometer
7012
1-turn potentiometer, 1 kΩ
7015
1-turn potentiometer, 10 kΩ
7016
1-turn potentiometer, 100 kΩ
7020
Knob for 1-turn potentiometer
7020A
Knob for 10-turn potentiometer
7028
10-turn potentiometer, 2 kΩ
8201L
Power wire