ADD TO QUOTE LIST
3333
Pt100 converter, loop-powered
High accuracy, better than 0.1% of span
Slimline housing of 6 mm
Excellent EMC performance and 50/60 Hz noise suppression
Selectable < 30 ms / 300 ms response time
Pre-calibrated temperature ranges selectable via DIP-switches
Overview
+
Technical details
+
Accessories
+
Application
The 3333 temperature converter measures a standard 2-, 3- or 4-wire Pt100 temperature sensor, and provides a passive analog current output signal.
The 3333 can be mounted in the safe area or in Zone 2 / Division 2 areas.
Approved for marine applications.
Technical characteristics
Flexibly loop powered by 3.3...35 VDC via connectors.
< 30 ms fast response time with simultaneous sensor error detection when selected.
Selectable 300 ms response time when signal dampening is needed.
High conversion accuracy in all available ranges, better than 0.1% of span.
Meeting the NAMUR NE21 recommendations, the 3333 provides top measurement performance in harsh EMC environments.
The device meets the NAMUR NE43 standard defining out of range and sensor error output values.
All terminals are protected against overvoltage and polarity error.
Excellent signal/noise ratio of > 60 dB.
Mounting / installation / programming
Selectable DIP-settings for easy configuration of more than 1000 factory calibrated measurement ranges.
The narrow 6 mm housing allows up to 165 units to be mounted per meter of DIN rail, without any air gap between units.
Wide ambient temperature range of -25...+70°C.
Declaration of Conformity
Metrology Pattern Approval (MPA)
Environmental Conditions
Operating temperature
-25°C to +70°C
Storage temperature
-40°C to +85°C
Calibration temperature
20...28°C
Relative humidity
< 95% RH (non-cond.)
Protection degree
IP20
Installation in
Pollution degree 2 & meas. / overvoltage cat. II
Mechanical specifications
Dimensions (HxWxD)
113 x 6.1 x 115 mm
Weight approx.
70 g
DIN rail type
DIN EN 60715/35 mm
Wire size
0.13...2.5 mm2 / AWG 26...12 stranded wire
Screw terminal torque
0.5 Nm
Vibration
IEC 60068-2-6
2...25 Hz
±1.6 mm
25...100 Hz
±4 g
Common specifications
Supply voltage
3.3...35 VDC
Max. required power
0.80 W
Internal power dissipation
12 mW...0.8 W
Response time (0...90%, 100...10%)
< 30 ms / 300 ms (selectable)
Voltage drop
3.3 VDC
Signal / noise ratio
Min. 60 dB
Programming
DIP-switches
Signal dynamics, input
23 bit
Signal dynamics, output
18 bit
EMC immunity influence
< ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst
< ±1% of span
Incorrect DIP-switch setting identification
3.5 mA
Input specifications
Temperature range, Pt100
-200...+850°C
Min. measurement range (span)
10°C
Accuracy: the greater of
Better than 0.1% of span or 0.2°C
Temperature coefficient: the greater of
0.02°C/°C or ≤ ±0.01%/°C
Sensor current
< 150 µA
Sensor cable resistance
< 50 Ω per wire
Effect of sensor cable resistance (3-/4-wire)
< 0.002 Ω / Ω
Sensor error detection
Yes - selectable via DIP-switch
Broken sensor detection
> 800 Ω
Shorted sensor detection
< 18 Ω
Output specifications
Updating time
10 ms
Programmable signal ranges
4...20 and 20...4 mA
Load (@ current output)
≤ (Vsupply - 3.3) / 0.023 [Ω]
Load stability
≤ 0.01% of span / 100 Ω
Sensor error indication
3.5 mA or 23 mA / acc. to NAMUR NE43 or OFF
I.S. / Ex marking
ATEX
II 3 G Ex ec IIC T4 Gc
IECEx
Ex ec IIC T4 Gc
FM, US
Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4
FM, CA
Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4
EAC Ex
2Ex nA IIC T4 Gc X
Observed authority requirements
EMC
2014/30/EU
LVD
2014/35/EU
ATEX
2014/34/EU
RoHS
2011/65/EU
EAC
TR-CU 020/2011
EAC Ex
TR-CU 012/2011
Approvals
ATEX
KEMA 10ATEX0147 X
IECEx
KEM 10.0068X
c FM us
FM17US0004X / FM17CA0003X
c UL us, UL 61010-1
E314307
EAC Ex
RU C-DK.HA65.B.00355/19
DNV Marine
TAA00001RW
Is this information helpful?